Arrhythmic episodes in patients implanted with a cardioverter-defibrillator - results from the Prospective Study on Predictive Quality with Preferencing PainFree ATP therapies (4P).


ABSTRACT: BACKGROUND:Little is known about the ICD performance using enhanced detection algorithms in unselected, non-trial patients. Performance of recent generation ICD equipped with SmartShock™ technology (SST) for detection and conversion of ventricular tachyarrhythmias (VTA) was investigated. METHODS:4P was a prospective, multicenter, observational study conducted in 10 Swiss implanting centers. Patients with a Class I indication according to international guidelines were included and received an ICD with SST. ICD discrimination capability was assessed by evaluating SST performance; therapy efficacy was assessed by rate of VTA conversions by ATP and by rescue shocks. RESULTS:Overall, 196 patients were included in the analysis with a mean duration of follow-up of 27.7?months (452 patient-years of observation). Patient-specific rather than recommended programming was preferred. Device-detected episodes were frequent (5147 episodes in 146 patients, 74.5%). In 44 patients (22.4%), 1274 episodes were categorized as VTA; only 215 episodes were symptomatic. ATP was the first-line therapy and highly effective (99.9% success rate at the episode level, 100.0% at the patient level). Rescue shocks were rare (66 episodes in 28 patients); 7 shocks in 5 patients (2.6%) were inappropriate. Death and hospitalization rates were low. CONCLUSIONS:In a cohort of non-trial, unselected ICD patients, VTA episodes were frequent. The 4P results confirm the robustness of VTA detection by SST and the effectiveness of ATP treatment, hence limiting overall ICD shock burden.

SUBMITTER: Regoli F 

PROVIDER: S-EPMC6580638 | biostudies-literature | 2019 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Arrhythmic episodes in patients implanted with a cardioverter-defibrillator - results from the Prospective Study on Predictive Quality with Preferencing PainFree ATP therapies (4P).

Regoli François F   Graf Denis D   Schaer Beat B   Duru Firat F   Ammann Peter P   Stefano Lorenza Mangoni di S LMDS   Naegli Barbara B   Burri Haran H   Zbinden Rainer R   Krasniqi Nazmi N   Fromer Martin M  

BMC cardiovascular disorders 20190617 1


<h4>Background</h4>Little is known about the ICD performance using enhanced detection algorithms in unselected, non-trial patients. Performance of recent generation ICD equipped with SmartShock™ technology (SST) for detection and conversion of ventricular tachyarrhythmias (VTA) was investigated.<h4>Methods</h4>4P was a prospective, multicenter, observational study conducted in 10 Swiss implanting centers. Patients with a Class I indication according to international guidelines were included and  ...[more]

Similar Datasets

| S-EPMC8892042 | biostudies-literature
| S-EPMC6743319 | biostudies-literature
| S-EPMC5612865 | biostudies-other
| S-EPMC6276371 | biostudies-literature
| S-EPMC8174382 | biostudies-literature
| S-EPMC5491470 | biostudies-other
| S-EPMC5089470 | biostudies-literature
| S-EPMC8747379 | biostudies-literature
| S-EPMC7360169 | biostudies-literature
| S-EPMC7071569 | biostudies-literature