Unknown

Dataset Information

0

Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability.


ABSTRACT: Background:Several radiographic measurements of the humerus can be used to evaluate the treatment outcome of supracondylar fractures in children. Because of the cartilaginous nature of the immature elbow, interpretation of radiographs around this area is sometimes challenging and can be unreliable. This study was conducted to determine the inter-observer and intra-observer reliability of the six commonly used radiographic measurements of the distal humerus. Method:The Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle and lateral capitellohumeral angle of the humerus were measured by two observers on the radiographs of uninjured elbows from 58 children. The values between each measurement were compared and correlated using a Pearson coefficient of correlation to determine the inter-observer and intra-observer reliability. Results:All of the radiographic parameters showed excellent intra-observer reliability with the correlation coefficient values of the Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle, lateral capitellohumeral angle as 0.945, 0.95, 0.909, 0.888, 0.961 and 0.975 (p?

SUBMITTER: Suangyanon P 

PROVIDER: S-EPMC6612040 | biostudies-literature | 2019 Jul-Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability.

Suangyanon Purinon P   Chalayon Ornusa O   Worawuthangkul Kitti K   Kaewpornsawan Kamolporn K   Ariyawatkul Thanase T   Eamsobhana Perajit P  

Journal of clinical orthopaedics and trauma 20180723 4


<h4>Background</h4>Several radiographic measurements of the humerus can be used to evaluate the treatment outcome of supracondylar fractures in children. Because of the cartilaginous nature of the immature elbow, interpretation of radiographs around this area is sometimes challenging and can be unreliable. This study was conducted to determine the inter-observer and intra-observer reliability of the six commonly used radiographic measurements of the distal humerus.<h4>Method</h4>The Baumann angl  ...[more]

Similar Datasets

| S-EPMC3552977 | biostudies-literature
| S-EPMC5525479 | biostudies-other
| S-EPMC4869743 | biostudies-literature
| S-EPMC5538093 | biostudies-other
| S-EPMC4509850 | biostudies-literature
| S-EPMC7066724 | biostudies-literature
| S-EPMC3851735 | biostudies-literature
| S-EPMC7114789 | biostudies-literature
| S-EPMC4462010 | biostudies-literature
| S-EPMC10813881 | biostudies-literature