Water removal in MR spectroscopic imaging with L2 regularization.


ABSTRACT: PURPOSE:An L2-regularization based postprocessing method is proposed and tested for removal of residual or unsuppressed water signals in proton MR spectroscopic imaging (MRSI) data recorded from the human brain at 3T. METHODS:Water signals are removed by implementation of the L2 regularization using a synthesized water-basis matrix that is orthogonal to metabolite signals of interest in the spectral dimension. Simulated spectra with variable water amplitude and in vivo brain MRSI datasets were used to demonstrate the proposed method. Results were compared with two commonly-used postprocessing methods for removing water signals. RESULTS:The L2 method yielded metabolite signals that were close to true values for the simulated spectra. Residual/unsuppressed water signals in human brain short- and long-echo time MRSI datasets were efficiently removed by the proposed method allowing good quality metabolite maps to be reconstructed with minimized contamination from water signals. Significant differences of the creatine signal were observed between brain long-echo time MRSI without and with water saturation, attributable to the previously described magnetization transfer effect. CONCLUSIONS:With usage of a synthesized water matrix generated based on reasonable prior knowledge about water and metabolite resonances, the L2 method is shown to be an effective way to remove water signals from MRSI of the human brain.

SUBMITTER: Lin L 

PROVIDER: S-EPMC6626566 | biostudies-literature | 2019 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Water removal in MR spectroscopic imaging with L2 regularization.

Lin Liangjie L   Považan Michal M   Berrington Adam A   Chen Zhong Z   Barker Peter B PB  

Magnetic resonance in medicine 20190531 4


<h4>Purpose</h4>An L2-regularization based postprocessing method is proposed and tested for removal of residual or unsuppressed water signals in proton MR spectroscopic imaging (MRSI) data recorded from the human brain at 3T.<h4>Methods</h4>Water signals are removed by implementation of the L2 regularization using a synthesized water-basis matrix that is orthogonal to metabolite signals of interest in the spectral dimension. Simulated spectra with variable water amplitude and in vivo brain MRSI  ...[more]

Similar Datasets

| S-EPMC4945498 | biostudies-literature
| S-EPMC2917802 | biostudies-other
| S-EPMC7975598 | biostudies-literature
| S-EPMC2897693 | biostudies-other
| S-EPMC2944924 | biostudies-literature
| S-EPMC6347534 | biostudies-literature
| S-EPMC5513734 | biostudies-literature
| S-EPMC8244067 | biostudies-literature
| S-EPMC3380413 | biostudies-other
| S-EPMC2680166 | biostudies-literature