Unknown

Dataset Information

0

Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial.


ABSTRACT: Purpose: To compare virtual planning accuracy of novel computer-assisted, template-based implant placement techniques, which make use of CAD/CAM stereolithographic surgical templates with or without metallic sleeves. Furthermore, to compare open versus closed sleeves for templates without metallic sleeves. Materials and methods: Any partially edentulous patients requiring at least one implant to be placed according to a computer-assisted template-based protocol were enrolled. Patients were randomized according to a parallel group design into two arms: Surgical template with or without metallic sleeves. Three deviation parameters (angular, horizontal, vertical) were defined to evaluate the discrepancy between the planned and placed implant positions. Results: No implants failed, and no complications were experienced. Forty-one implants were placed using surgical templates with metallic sleeves while 49 implants were placed with a surgical template without metallic sleeves. Of these, 16 implants were placed through open sleeves and 33 through closed sleeves. There was a statistically significant difference in angle (p = 0.0212) and in the vertical plan (p = 0.0073) with lower values for implants placed with a surgical template without metallic sleeves. In the test group, close sleeves were more accurate compared with open sleeves in angle (p = 0.0268) and in horizontal plan (p = 0.0477). Conclusion: With the limitations of the present study, surgical templates without metallic sleeves were more accurate in the vertical plan and angle compared to the conventional template with metallic sleeves. Open sleeves should be used with caution in the molar region only in case of reduced interarch space. Further research is needed to confirm these preliminary results.

SUBMITTER: Tallarico M 

PROVIDER: S-EPMC6631019 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial.

Tallarico Marco M   Martinolli Matteo M   Kim Yongjin Y   Cocchi Fabio F   Meloni Silvio Mario SM   Alushi Adem A   Xhanari Erta E  

Dentistry journal 20190402 2


<b>Purpose:</b> To compare virtual planning accuracy of novel computer-assisted, template-based implant placement techniques, which make use of CAD/CAM stereolithographic surgical templates with or without metallic sleeves. Furthermore, to compare open versus closed sleeves for templates without metallic sleeves. <b>Materials and methods</b>: Any partially edentulous patients requiring at least one implant to be placed according to a computer-assisted template-based protocol were enrolled. Patie  ...[more]

Similar Datasets

| S-EPMC7502099 | biostudies-literature
| S-EPMC10439617 | biostudies-literature
| S-EPMC8833256 | biostudies-literature
| S-EPMC5438863 | biostudies-literature
| S-EPMC10455221 | biostudies-literature
| S-EPMC9305866 | biostudies-literature
| S-EPMC7579824 | biostudies-literature
| S-EPMC7142455 | biostudies-literature
| S-EPMC7064711 | biostudies-literature
| S-EPMC4740842 | biostudies-other