Unknown

Dataset Information

0

Multipoint Fiber Loop Ringdown Sensors for Large Strain Measurement Using Frequency-Shifted Interferometry.


ABSTRACT: A novel multipoint fiber loop ringdown (FLRD) strain sensing system using frequency-shifted interferometry (FSI) is proposed and experimentally validated. Compared to conventional multipoint FLRD techniques, this scheme measures the decay rate of the continuous wave (CW) light in the space domain and thus greatly reduces the cost without the requirement of expensive devices. A serial dual-point strain sensing system was experimentally constructed and a biconical tapered multimode fiber (MMF) as the sensor head was used for obtaining the large measuring range. By applying different strains on the sensor heads through translation stages, a linear response between strain and additional loss induced by strain sensor was obtained, and the static strain sensitivities of 0.13676 dB/m? and 0.19665 dB/m? were achieved, corresponding to the detection limit of 0.0123 dB and 0.0360 dB, respectively. Moreover, a large measuring range of approximately 6 m? was achieved for both strain sensors. The experimental results indicate that our proposed method offers a promising multipoint strain sensor which has the advantages of low cost, a simple sensing structure and a large measuring range.

SUBMITTER: Cheng C 

PROVIDER: S-EPMC6651694 | biostudies-literature | 2019 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multipoint Fiber Loop Ringdown Sensors for Large Strain Measurement Using Frequency-Shifted Interferometry.

Cheng Chunfu C   Chen Zehao Z   Ou Yiwen Y   Chen Jiaxuan J  

Sensors (Basel, Switzerland) 20190701 13


A novel multipoint fiber loop ringdown (FLRD) strain sensing system using frequency-shifted interferometry (FSI) is proposed and experimentally validated. Compared to conventional multipoint FLRD techniques, this scheme measures the decay rate of the continuous wave (CW) light in the space domain and thus greatly reduces the cost without the requirement of expensive devices. A serial dual-point strain sensing system was experimentally constructed and a biconical tapered multimode fiber (MMF) as  ...[more]

Similar Datasets

| S-EPMC4664374 | biostudies-literature
| S-EPMC6386780 | biostudies-literature
| S-EPMC6804567 | biostudies-literature
| S-EPMC4588503 | biostudies-other
| S-EPMC5847515 | biostudies-other
| S-EPMC5897385 | biostudies-literature
| S-EPMC7007000 | biostudies-literature
| S-EPMC5855488 | biostudies-literature
| S-EPMC5469539 | biostudies-literature