Unknown

Dataset Information

0

Next-generation sequencing using microfluidic PCR enrichment for molecular autopsy.


ABSTRACT: BACKGROUND:We aimed to determine the mutation yield and clinical applicability of "molecular autopsy" following sudden arrhythmic death syndrome (SADS) by validating and utilizing low-cost high-throughput technologies: Fluidigm Access Array PCR-enrichment with Illumina HiSeq 2000 next generation sequencing (NGS). METHODS:We validated and optimized the NGS platform with a subset of 46 patients by comparison with Sanger sequencing of coding exons of major arrhythmia risk-genes (KCNQ1, KCNH2, SCN5A, KCNE1, KCNE2, RYR2). A combined large multi-ethnic international SADS cohort was sequenced utilizing the NGS platform to determine overall molecular yield; rare variants identified by NGS were subsequently reconfirmed by Sanger sequencing. RESULTS:The NGS platform demonstrated 100% sensitivity for pathogenic variants as well as 87.20% sensitivity and 99.99% specificity for all substitutions (optimization subset, n?=?46). The positive predictive value (PPV) for NGS for rare substitutions was 16.0% (27 confirmed rare variants of 169 positive NGS calls in 151 additional cases). The overall molecular yield in 197 multi-ethnic SADS cases (mean age 22.6?±?14.4?years, 68% male) was 5.1% (95% confidence interval 2.0-8.1%), representing 10 cases carrying pathogenic or likely pathogenic risk-mutations. CONCLUSIONS:Molecular autopsy with Fluidigm Access Array and Illumina HiSeq NGS utilizing a selected panel of LQTS/BrS and CPVT risk-genes offers moderate diagnostic yield, albeit requiring confirmatory Sanger-sequencing of mutational variants.

SUBMITTER: Raju H 

PROVIDER: S-EPMC6651896 | biostudies-literature | 2019 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>We aimed to determine the mutation yield and clinical applicability of "molecular autopsy" following sudden arrhythmic death syndrome (SADS) by validating and utilizing low-cost high-throughput technologies: Fluidigm Access Array PCR-enrichment with Illumina HiSeq 2000 next generation sequencing (NGS).<h4>Methods</h4>We validated and optimized the NGS platform with a subset of 46 patients by comparison with Sanger sequencing of coding exons of major arrhythmia risk-genes (KCNQ  ...[more]

Similar Datasets

| S-EPMC4678842 | biostudies-literature
| S-EPMC4049327 | biostudies-other
| S-EPMC4104715 | biostudies-literature
| 41336 | ecrin-mdr-crc
| S-EPMC5398417 | biostudies-literature
| S-EPMC3774667 | biostudies-literature
| S-EPMC4764375 | biostudies-literature
2017-04-03 | PXD003804 | Pride
| S-EPMC6945761 | biostudies-literature
| S-EPMC8404235 | biostudies-literature