Unknown

Dataset Information

0

Multiplex Real-Time PCR-shortTUB Assay for Detection of the Mycobacterium tuberculosis Complex in Smear-Negative Clinical Samples with Low Mycobacterial Loads.


ABSTRACT: Tuberculosis (TB) remains a major health problem worldwide. Control of TB requires rapid, accurate diagnosis of active disease. However, extrapulmonary TB is very difficult to diagnose because the clinical specimens have very low bacterial loads. Several molecular methods involving direct detection of the Mycobacterium tuberculosis complex (MTBC) have emerged in recent years. Real-time PCR amplification simultaneously combines the amplification and detection of candidate sequences by using fluorescent probes (mainly TaqMan or Molecular Beacons) in automated systems. The multiplex real-time PCR-short assay is performed using locked nucleic acid (LNA) probes (length, 8 to 9 nucleotides) in combination with CodUNG to detect multiple pathogens in clinical samples. In this study, we evaluated the performance of this novel multiplex assay for detecting the MTBC in comparison with that of the conventional culture-based method. The multiplex real-time PCR-shortTUB assay targets two genes, whiB3 (redox-responsive transcriptional regulator) and pstS1 (phosphate-specific transporter), yielding limits of detection (LOD) of 10 copies and 100 copies, respectively, and amplification efficiencies of 92% and 99.7%, respectively. A total of 94 extrapulmonary samples and pulmonary samples with low mycobacterial loads (all smear negative; 75 MTBC culture positive) were analyzed using the test, yielding an overall sensitivity of 88% and a specificity of 95%. For pleural fluid and tissues/biopsy specimens, the sensitivity was 83% and 85%, respectively. In summary, this technique could be implemented in routine clinical microbiology testing to reduce the overall turnaround time for MTBC detection and may therefore be a useful tool for the diagnosis of extrapulmonary tuberculosis and diagnosis using pulmonary samples with low mycobacterial loads.

SUBMITTER: Alcaide F 

PROVIDER: S-EPMC6663905 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multiplex Real-Time PCR-short<sub>TUB</sub> Assay for Detection of the Mycobacterium tuberculosis Complex in Smear-Negative Clinical Samples with Low Mycobacterial Loads.

Alcaide Fernando F   Trastoy Rocío R   Moure Raquel R   González-Bardanca Mónica M   Ambroa Antón A   López María M   Bleriot Inés I   Blasco Lucia L   Fernandez-García Laura L   Tato Marta M   Bou German G   Tomás María M  

Journal of clinical microbiology 20190726 8


Tuberculosis (TB) remains a major health problem worldwide. Control of TB requires rapid, accurate diagnosis of active disease. However, extrapulmonary TB is very difficult to diagnose because the clinical specimens have very low bacterial loads. Several molecular methods involving direct detection of the <i>Mycobacterium tuberculosis</i> complex (MTBC) have emerged in recent years. Real-time PCR amplification simultaneously combines the amplification and detection of candidate sequences by usin  ...[more]

Similar Datasets

| S-EPMC3043491 | biostudies-literature
| S-EPMC3264165 | biostudies-literature
| S-EPMC262464 | biostudies-literature
| S-EPMC1393095 | biostudies-literature
| S-EPMC5820066 | biostudies-literature
| S-EPMC4390653 | biostudies-literature
| S-EPMC525196 | biostudies-literature
| S-EPMC254334 | biostudies-literature
| S-EPMC3405619 | biostudies-literature
| S-EPMC2564954 | biostudies-literature