Ontology highlight
ABSTRACT: Background
Several randomised controlled trials show that maintenance of labour epidural analgesia with programmed intermittent epidural bolus reduces the maternal motor block compared with maintenance with a continuous infusion. However, these trials were usually restricted to healthy nulliparous parturients. To assess the generalisability of these randomised controlled trials to 'real-world' conditions, we compared maternal motor function (modified Bromage score) over time between healthy nulliparous and parous women using routinely collected quality-control data.Methods
After ethical approval, all parturients receiving programmed intermittent epidural bolus labour analgesia between June 2013 and October 2014 were included in this prospective cohort study. Bupivacaine 0.1% with fentanyl 2 ?g ml-1 was used allowing for patient-controlled bolus every 20 min. The maternal motor function (primary outcome) was regularly assessed from insertion of the epidural catheter until delivery.Results
Of the 839 parturients included, 553 (66%) were nulliparous and 286 (34%) were parous. The parous women had a shorter median duration of epidural analgesia (3 h 59 min vs 5 h 45 min) and a higher incidence of spontaneous delivery (66% vs 37%). The probability of being in a certain Bromage category at birth was similar in nulliparous and parous women in a general additive model adjusting for duration of epidural analgesia, number of rescue top-ups, and number of catheter manipulations (cumulative odds ratio: 1.18; 95% confidence interval: 0.98-1.41). Parous women required a higher time-weighted number and volume of rescue top-ups.Conclusions
The results of the randomised controlled trials on a reduced motor block with programmed intermittent epidural bolus seem generalisable to parturients typically not included in these trials.
SUBMITTER: Gabriel L
PROVIDER: S-EPMC6676019 | biostudies-literature | 2019 Aug
REPOSITORIES: biostudies-literature
Gabriel L L Young J J Hoesli I I Girard T T Dell-Kuster S S
British journal of anaesthesia 20190328 2
<h4>Background</h4>Several randomised controlled trials show that maintenance of labour epidural analgesia with programmed intermittent epidural bolus reduces the maternal motor block compared with maintenance with a continuous infusion. However, these trials were usually restricted to healthy nulliparous parturients. To assess the generalisability of these randomised controlled trials to 'real-world' conditions, we compared maternal motor function (modified Bromage score) over time between heal ...[more]