Unknown

Dataset Information

0

In vitro examination of the thrombolytic efficacy of tenecteplase and therapeutic ultrasound compared to rt-PA.


ABSTRACT: BACKGROUND:Optimizing thrombolytic therapy is vital for improving stroke outcomes. We aimed to develop standardized thrombolysis conditions to evaluate the efficacy of tenecteplase (TNK) compared to the current gold standard rt-PA (alteplase), with and without additional ultrasound treatment. We also wanted to introduce a new analytical approach to quantify fibrin fiber density in transmission electron microscopy (TEM). METHODS:In vitro clots that are similar to ex vivo clots concerning their histological condition and their durability were generated from whole blood. For five treatment groups we compared relative clot weight loss (each n =?60) and fibrin fiber density in TEM (each n =?5). The control group (A) was treated only with plasma. Two groups were designated for each rt-PA (B?+?C) and TNK (D?+?E). Groups C and E were additionally treated with ultrasound. Dosages were 50??g/ml for rt-PA and 30??g/ml for TNK. Results were evaluated by using analyses of variance (ANOVA) and post-hoc t-tests. RESULTS:Weight loss was increased significantly for all groups compared to the control group. Both TNK groups showed significantly increased weight loss compared to their counterpart rt-PA group (p ??0.001). For TEM only group D showed significantly decreased fibrin fiber density (p 

SUBMITTER: Fruhwald T 

PROVIDER: S-EPMC6676584 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

In vitro examination of the thrombolytic efficacy of tenecteplase and therapeutic ultrasound compared to rt-PA.

Frühwald Tobias T   Gärtner Ulrich U   Stöckmann Nils N   Marxsen Jan-Henning JH   Gramsch Carolin C   Roessler Florian C FC  

BMC neurology 20190802 1


<h4>Background</h4>Optimizing thrombolytic therapy is vital for improving stroke outcomes. We aimed to develop standardized thrombolysis conditions to evaluate the efficacy of tenecteplase (TNK) compared to the current gold standard rt-PA (alteplase), with and without additional ultrasound treatment. We also wanted to introduce a new analytical approach to quantify fibrin fiber density in transmission electron microscopy (TEM).<h4>Methods</h4>In vitro clots that are similar to ex vivo clots conc  ...[more]

Similar Datasets

| S-EPMC3621317 | biostudies-other
| S-EPMC5563443 | biostudies-literature
| S-EPMC9362569 | biostudies-literature
| S-EPMC2633628 | biostudies-literature
| S-EPMC2695447 | biostudies-other
| S-EPMC6449915 | biostudies-literature
| S-EPMC8184783 | biostudies-literature
| S-EPMC2720797 | biostudies-literature
| S-EPMC5897498 | biostudies-literature
| S-EPMC3507518 | biostudies-literature