Nanoscale Intelligent Imaging Based on Real-Time Analysis of Approach Curve by Scanning Electrochemical Microscopy.


ABSTRACT: Scanning electrochemical microscopy (SECM) enables high-resolution imaging by examining the amperometric response of an ultramicroelectrode tip near a substrate. Spatial resolution, however, is compromised for nonflat substrates, where distances from a tip far exceed the tip size to avoid artifacts caused by the tip-substrate contact. Herein, we propose a new imaging mode of SECM based on real-time analysis of the approach curve to actively control nanoscale tip-substrate distances without contact. The power of this software-based method is demonstrated by imaging an insulating substrate with step edges using standard instrumentation without combination of another method for distance measurement, e.g., atomic force microscopy. An ?500 nm diameter Pt tip approaches down to ?50 nm from upper and lower terraces of a 500 nm height step edge, which are located by real-time theoretical fitting of an experimental approach curve to ensure the lack of electrochemical reactivity. The tip approach to the step edge can be terminated at <20 nm prior to the tip-substrate contact as soon as the theory deviates from the tip current, which is analyzed numerically afterward to locate the inert edge. The advantageous local adjustment of tip height and tip current at the final point of tip approach distinguishes the proposed imaging mode from other modes based on standard instrumentation. In addition, the glass sheath of the Pt tip is thinned to ?150 nm to rarely contact the step edge, which is unavoidable and instantaneously detected as an abrupt change in the slope of approach curve to prevent damage of the fragile nanotip.

SUBMITTER: Balla RJ 

PROVIDER: S-EPMC6685738 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Nanoscale Intelligent Imaging Based on Real-Time Analysis of Approach Curve by Scanning Electrochemical Microscopy.

Balla Ryan J RJ   Jantz Dylan T DT   Kurapati Niraja N   Chen Ran R   Leonard Kevin C KC   Amemiya Shigeru S  

Analytical chemistry 20190729 15


Scanning electrochemical microscopy (SECM) enables high-resolution imaging by examining the amperometric response of an ultramicroelectrode tip near a substrate. Spatial resolution, however, is compromised for nonflat substrates, where distances from a tip far exceed the tip size to avoid artifacts caused by the tip-substrate contact. Herein, we propose a new imaging mode of SECM based on real-time analysis of the approach curve to actively control nanoscale tip-substrate distances without conta  ...[more]

Similar Datasets

| S-EPMC8862294 | biostudies-literature
| S-EPMC3406860 | biostudies-other
| S-EPMC3338092 | biostudies-literature
| S-EPMC8179569 | biostudies-literature
| S-EPMC4280622 | biostudies-literature
| S-EPMC8179047 | biostudies-literature
| S-EPMC4821995 | biostudies-literature
| S-EPMC4742556 | biostudies-literature
| S-EPMC9586107 | biostudies-literature
| S-EPMC3572272 | biostudies-literature