Test-retest reliability of a smartphone app for measuring core stability for two dynamic exercises.


ABSTRACT:

Background

Recently, there has been growing interest in using smartphone applications to assess gait speed and quantify isometric core stability exercise intensity. The purpose of this study was to investigate the between-session reliability and minimal detectable change of a smartphone app for two dynamic exercise tests of the lumbopelvic complex.

Methods

Thirty-three healthy young and active students (age: 22.3 ± 5.9 years, body weight: 66.9 ± 11.3 kg, height: 167.8 ± 10.3 cm) participated in this study. Intraclass correlation coefficient (ICC), coefficient of variation (%CV), and Bland-Altman plots were used to verify the reliability of the test. The standard error of measurement (SEM) and the minimum detectable difference (MDD) were calculated for clinical applicability.

Results

The ICCs ranged from 0.73 to 0.96, with low variation (0.9% to 4.8%) between days of assessments. The Bland-Altman plots and one-sample t-tests (p > 0.05) indicated that no dynamic exercise tests changed systematically. Our analyses showed that SEM 0.6 to 1.5 mm/s-2) and MDD (2.1 to 3.5 mm/s-2).

Conclusion

The OCTOcore app is a reliable tool to assess core stability for two dynamic exercises. A minimal change of 3.5 mm/s-2 is needed to be confident that the change is not a measurement error between two sessions.

SUBMITTER: Guillen-Rogel P 

PROVIDER: S-EPMC6690332 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

Test-retest reliability of a smartphone app for measuring core stability for two dynamic exercises.

Guillén-Rogel Paloma P   Franco-Escudero Cristina C   Marín Pedro J PJ  

PeerJ 20190809


<h4>Background</h4>Recently, there has been growing interest in using smartphone applications to assess gait speed and quantify isometric core stability exercise intensity. The purpose of this study was to investigate the between-session reliability and minimal detectable change of a smartphone app for two dynamic exercise tests of the lumbopelvic complex.<h4>Methods</h4>Thirty-three healthy young and active students (age: 22.3 ± 5.9 years, body weight: 66.9 ± 11.3 kg, height: 167.8 ± 10.3 cm) p  ...[more]

Similar Datasets

| S-EPMC7822719 | biostudies-literature
| S-EPMC8633424 | biostudies-literature
| S-EPMC6281233 | biostudies-literature
| S-EPMC4654759 | biostudies-literature
| S-EPMC4788471 | biostudies-other
| S-EPMC6118382 | biostudies-literature
| S-EPMC4547115 | biostudies-literature
| S-EPMC5568997 | biostudies-literature