Unknown

Dataset Information

0

Fall Risk Classification in Community-Dwelling Older Adults Using a Smart Wrist-Worn Device and the Resident Assessment Instrument-Home Care: Prospective Observational Study.


ABSTRACT:

Background

 Little is known about whether off-the-shelf wearable sensor data can contribute to fall risk classification or complement clinical assessment tools such as the Resident Assessment Instrument-Home Care (RAI-HC).

Objective

 This study aimed to (1) investigate the similarities and differences in physical activity (PA), heart rate, and night sleep in a sample of community-dwelling older adults with varying fall histories using a smart wrist-worn device and (2) create and evaluate fall risk classification models based on (i) wearable data, (ii) the RAI-HC, and (iii) the combination of wearable and RAI-HC data.

Methods

 A prospective, observational study was conducted among 3 faller groups (G0, G1, G2+) based on the number of previous falls (0, 1, ?2 falls) in a sample of older community-dwelling adults. Each participant was requested to wear a smart wristband for 7 consecutive days while carrying out day-to-day activities in their normal lives. The wearable and RAI-HC assessment data were analyzed and utilized to create fall risk classification models, with 3 supervised machine learning algorithms: logistic regression, decision tree, and random forest (RF).

Results

 Of 40 participants aged 65 to 93 years, 16 (40%) had no previous falls, whereas 8 (20%) and 16 (40%) had experienced 1 and multiple (?2) falls, respectively. Level of PA as measured by average daily steps was significantly different between groups (P=.04). In the 3 faller group classification, RF achieved the best accuracy of 83.8% using both wearable and RAI-HC data, which is 13.5% higher than that of using the RAI-HC data only and 18.9% higher than that of using wearable data exclusively. In discriminating between {G0+G1} and G2+, RF achieved the best area under the receiver operating characteristic curve of 0.894 (overall accuracy of 89.2%) based on wearable and RAI-HC data. Discrimination between G0 and {G1+G2+} did not result in better classification performance than that between {G0+G1} and G2+.

Conclusions

 Both wearable data and the RAI-HC assessment can contribute to fall risk classification. All the classification models revealed that RAI-HC outperforms wearable data, and the best performance was achieved with the combination of 2 datasets. Future studies in fall risk assessment should consider using wearable technologies to supplement resident assessment instruments.

SUBMITTER: Yang Y 

PROVIDER: S-EPMC6716444 | biostudies-literature | 2019 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Fall Risk Classification in Community-Dwelling Older Adults Using a Smart Wrist-Worn Device and the Resident Assessment Instrument-Home Care: Prospective Observational Study.

Yang Yang Y   Hirdes John P JP   Dubin Joel A JA   Lee Joon J  

JMIR aging 20190607 1


<h4>Background</h4> Little is known about whether off-the-shelf wearable sensor data can contribute to fall risk classification or complement clinical assessment tools such as the Resident Assessment Instrument-Home Care (RAI-HC).<h4>Objective</h4> This study aimed to (1) investigate the similarities and differences in physical activity (PA), heart rate, and night sleep in a sample of community-dwelling older adults with varying fall histories using a smart wrist-worn device and (2) create and e  ...[more]

Similar Datasets

| S-EPMC7794504 | biostudies-literature
| S-EPMC5707431 | biostudies-literature
| S-EPMC6962225 | biostudies-literature
| S-EPMC6550265 | biostudies-literature
| S-EPMC6466172 | biostudies-literature