Feasibility of high spatiotemporal resolution for an abbreviated 3D radial breast MRI protocol.


ABSTRACT: PURPOSE:To develop a volumetric imaging technique with 0.8-mm isotropic resolution and 10-s/volume rate to detect and analyze breast lesions in a bilateral, dynamic, contrast-enhanced MRI exam. METHODS:A local low-rank temporal reconstruction approach that also uses parallel imaging and spatial compressed sensing was designed to create rapid volumetric frame rates during a contrast-enhanced breast exam (vastly undersampled isotropic projection [VIPR] spatial compressed sensing with temporal local low-rank [STELLR]). The dynamic-enhanced data are subtracted in k-space from static mask data to increase sparsity for the local low-rank approach to maximize temporal resolution. A T1 -weighted 3D radial trajectory (VIPR iterative decomposition with echo asymmetry and least squares estimation [IDEAL]) was modified to meet the data acquisition requirements of the STELLR approach. Additionally, the unsubtracted enhanced data are reconstructed using compressed sensing and IDEAL to provide high-resolution fat/water separation. The feasibility of the approach and the dual reconstruction methodology is demonstrated using a 16-channel breast coil and a 3T MR scanner in 6 patients. RESULTS:The STELLR temporal performance of subtracted data matched the expected temporal perfusion enhancement pattern in small and large vascular structures. Differential enhancement within heterogeneous lesions is demonstrated with corroboration from a basic reconstruction using a strict 10-second temporal footprint. Rapid acquisition, reliable fat suppression, and high spatiotemporal resolution are presented, despite significant data undersampling. CONCLUSION:The STELLR reconstruction approach of 3D radial sampling with mask subtraction provides a high-performance imaging technique for characterizing enhancing structures within the breast. It is capable of maintaining temporal fidelity, while visualizing breast lesions with high detail over a large FOV to include both breasts.

SUBMITTER: Jimenez JE 

PROVIDER: S-EPMC6721961 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Feasibility of high spatiotemporal resolution for an abbreviated 3D radial breast MRI protocol.

Jimenez Jorge E JE   Strigel Roberta M RM   Johnson Kevin M KM   Henze Bancroft Leah C LC   Reeder Scott B SB   Block Walter F WF  

Magnetic resonance in medicine 20180214 4


<h4>Purpose</h4>To develop a volumetric imaging technique with 0.8-mm isotropic resolution and 10-s/volume rate to detect and analyze breast lesions in a bilateral, dynamic, contrast-enhanced MRI exam.<h4>Methods</h4>A local low-rank temporal reconstruction approach that also uses parallel imaging and spatial compressed sensing was designed to create rapid volumetric frame rates during a contrast-enhanced breast exam (vastly undersampled isotropic projection [VIPR] spatial compressed sensing wit  ...[more]

Similar Datasets

| S-EPMC7653281 | biostudies-literature
| S-EPMC4065644 | biostudies-literature
| S-EPMC8324328 | biostudies-literature
| S-EPMC6619236 | biostudies-literature
| S-EPMC9203940 | biostudies-literature
| S-EPMC7286290 | biostudies-literature
| S-EPMC6920271 | biostudies-literature
| S-EPMC7067463 | biostudies-literature
| S-EPMC3743726 | biostudies-literature
| S-EPMC10703683 | biostudies-literature