Lung Stereotactic Body Radiation Therapy (SBRT) dose gradient and PTV volume: a retrospective multi-center analysis.


ABSTRACT: BACKGROUND:The treatment of lung lesions with stereotactic body radiation therapy calls for highly conformal dose, which is evaluated by a number of metrics. Lung stereotactic body radiation therapy clinical trials constrain a plans gradient index. The purpose of this work is to describe the dependence of clinically achievable dose gradient on planning target volume. METHODS:Three hundred seventy-four lung stereotactic body radiation therapy treatment plans were retrospectively reviewed and selected for this study. The relationship between R50% and planning target volume size was observed and compared against the RTOG 0915 and 0813 constraints noting minor and major deviations. Then a least squares regression was used to determine the coefficients for a power functional form of the dependence of gradient measure (GM) on planning target volume size. RESULTS:Of the 317 peripheral lung SBRT plans, 142 exhibited no deviation, 135 exhibited a minor deviation, and 40 exhibited a major deviation according to the RTOG 0915 dosimetric. conformality and dose fall-off constraints. A plot of gradient measure versus planning target volume size for peripheral lesions, excluding RTOG 0915 major deviations, is fit with an power function of GM?=?0.564?V0.215. CONCLUSIONS:Using the PTV size and GM relationship we have characterized, treatment plans with PTV?

SUBMITTER: Hoffman D 

PROVIDER: S-EPMC6724320 | biostudies-literature | 2019 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Lung Stereotactic Body Radiation Therapy (SBRT) dose gradient and PTV volume: a retrospective multi-center analysis.

Hoffman David D   Dragojević Irena I   Hoisak Jeremy J   Hoopes David D   Manger Ryan R  

Radiation oncology (London, England) 20190903 1


<h4>Background</h4>The treatment of lung lesions with stereotactic body radiation therapy calls for highly conformal dose, which is evaluated by a number of metrics. Lung stereotactic body radiation therapy clinical trials constrain a plans gradient index. The purpose of this work is to describe the dependence of clinically achievable dose gradient on planning target volume.<h4>Methods</h4>Three hundred seventy-four lung stereotactic body radiation therapy treatment plans were retrospectively re  ...[more]

Similar Datasets

| S-EPMC7641492 | biostudies-literature
| S-EPMC7217854 | biostudies-literature
| S-EPMC7655115 | biostudies-literature
| S-EPMC7481615 | biostudies-literature
| S-EPMC7406342 | biostudies-literature
| S-EPMC8281902 | biostudies-literature
| S-EPMC5830173 | biostudies-literature
| S-EPMC5718687 | biostudies-other
| S-EPMC7807546 | biostudies-literature
| S-EPMC3580772 | biostudies-literature