Acoustic feedback enables safe and reliable carboplatin delivery across the blood-brain barrier with a clinical focused ultrasound system and improves survival in a rat glioma model.


ABSTRACT: The blood-brain barrier (BBB) restricts delivery of most chemotherapy agents to brain tumors. Here, we investigated a clinical focused ultrasound (FUS) device to disrupt the BBB in rats and enhance carboplatin delivery to the brain using the F98 glioma model. Methods: In each rat, 2-3 volumetric sonications (5 ms bursts at 1.1 Hz for 75s) targeted 18-27 locations in one hemisphere. Sonication was combined with Definity microbubbles (10 µl/kg) and followed by intravenous carboplatin (50 mg/kg). Closed-loop feedback control was performed based on acoustic emissions analysis. Results: Safety and reliability were established in healthy rats after three sessions with carboplatin; BBB disruption was induced in every target without significant damage evident in MRI or histology. In tumor-bearing rats, concentrations of MRI contrast agent (Gadavist) were 1.7 and 3.3 times higher in the tumor center and margin, respectively, than non-sonicated tumors (P<0.001). Tissue-to-plasma ratios of intact carboplatin concentrations were increased by 7.3 and 2.9 times in brain and tumor respectively, at one hour after FUS and 4.2 and 2.4 times at four hours. Tumor volume doubling time in rats receiving FUS and carboplatin increased by 96% and 126% compared to rats that received carboplatin alone and non-sonicated controls, respectively (P<0.05); corresponding increases in median survival were 48% and 66% (P<0.01). Conclusion: Overall, this work demonstrates that actively-controlled BBB disruption with a clinical device can enhance carboplatin delivery without neurotoxicity at level that reduces tumor growth and improves survival in an aggressive and infiltrative rat glioma model.

SUBMITTER: McDannold N 

PROVIDER: S-EPMC6735504 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

Acoustic feedback enables safe and reliable carboplatin delivery across the blood-brain barrier with a clinical focused ultrasound system and improves survival in a rat glioma model.

McDannold Nathan N   Zhang Yongzhi Y   Supko Jeffrey G JG   Power Chanikarn C   Sun Tao T   Peng Chengueng C   Vykhodtseva Natalia N   Golby Alexandra J AJ   Reardon David A DA  

Theranostics 20190814 21


The blood-brain barrier (BBB) restricts delivery of most chemotherapy agents to brain tumors. Here, we investigated a clinical focused ultrasound (FUS) device to disrupt the BBB in rats and enhance carboplatin delivery to the brain using the F98 glioma model. <b>Methods</b>: In each rat, 2-3 volumetric sonications (5 ms bursts at 1.1 Hz for 75s) targeted 18-27 locations in one hemisphere. Sonication was combined with Definity microbubbles (10 µl/kg) and followed by intravenous carboplatin (50 mg  ...[more]

Similar Datasets

| S-EPMC3309801 | biostudies-other
| S-EPMC5964106 | biostudies-literature
| S-EPMC10981822 | biostudies-literature
| S-EPMC6934715 | biostudies-literature
| S-EPMC6702128 | biostudies-literature
| S-EPMC6540854 | biostudies-literature
| S-EPMC8449371 | biostudies-literature
| S-EPMC2815109 | biostudies-literature
| S-EPMC8615744 | biostudies-literature
| S-EPMC5996352 | biostudies-literature