One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition.


ABSTRACT: We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1?day, 1 week, 1, 3, 6, 9, and 12 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70?cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30?cm were measured. A defocus curve was obtained and patients were asked about the severity of photic phenomena. Postoperative distance and intermediate visual acuity was excellent, with UDVA, CDVA, UIVA, and DCIVA of approximately 20/20, 20/16, 20/25, 20/25 were attained, respectively. The level of near visual acuity was lower; UNVA and DCNVA remained at around 20/60 and 20/70, respectively. The defocus curve indicated that postoperative uncorrected visual acuity of 20/25 and 20/40 was obtained at as close as 67?cm and 50?cm, respectively. Contrast sensitivity was within the normal range, with a minimal level of subjective symptoms and high patient satisfaction. The rotationally asymmetric multifocal IOLs with +1.5 D near addition provided excellent distance and intermediate vision, but near vision was not enough for reading small prints. Contrast sensitivity was high, with very low incidences of photic phenomena and a high level of patient satisfaction.

SUBMITTER: Oshika T 

PROVIDER: S-EPMC6739307 | biostudies-literature | 2019 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition.

Oshika Tetsuro T   Arai Hiroyuki H   Fujita Yoshifumi Y   Inamura Mikio M   Inoue Yasushi Y   Noda Toru T   Miyata Kazunori K  

Scientific reports 20190911 1


We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1 day, 1 week, 1, 3, 6, 9, and 12 months after surgery. U  ...[more]

Similar Datasets

| S-EPMC6037343 | biostudies-literature
| S-EPMC8711202 | biostudies-literature
| S-EPMC8236945 | biostudies-literature
| S-EPMC7311225 | biostudies-literature
| S-EPMC5512912 | biostudies-other
| S-EPMC8149325 | biostudies-literature
| S-EPMC9322991 | biostudies-literature
| S-EPMC7782424 | biostudies-literature
| S-EPMC6181000 | biostudies-literature
| S-EPMC9200955 | biostudies-literature