Unknown

Dataset Information

0

Agreement between the spatiotemporal gait parameters from two different wearable devices and high-speed video analysis.


ABSTRACT: This study aimed to evaluate the concurrent validity of two different inertial measurement units for measuring spatiotemporal parameters during running on a treadmill, by comparing data with a high-speed video analysis (VA) at 1,000 Hz. Forty-nine endurance runners performed a running protocol on a treadmill at comfortable velocity (i.e., 3.25 ± 0.36 m.s-1). Those wearable devices (i.e., Stryd™ and RunScribe™ systems) were compared to a high-speed VA, as a reference system for measuring spatiotemporal parameters (i.e. contact time [CT], flight time [FT], step frequency [SF] and step length [SL]) during running at comfortable velocity. The pairwise comparison revealed that the Stryd™ system underestimated CT (5.2%, p < 0.001) and overestimated FT (15.1%, p < 0.001) compared to the VA; whereas the RunScribe™ system underestimated CT (2.3%, p = 0.009). No significant differences were observed in SF and SL between the wearable devices and VA. The intra class correlation coefficient (ICC) revealed an almost perfect association between both systems and high-speed VA (ICC > 0.81). The Bland-Altman plots revealed heteroscedasticity of error (r2 = 0.166) for the CT from the Stryd™ system, whereas no heteroscedasticity of error (r2 < 0.1) was revealed in the rest of parameters. In conclusion, the results obtained suggest that both foot pods are valid tools for measuring spatiotemporal parameters during running on a treadmill at comfortable velocity. If the limits of agreement of both systems are considered in respect to high-speed VA, the RunScribe™ seems to be a more accurate system for measuring temporal parameters and SL than the Stryd™ system.

SUBMITTER: Garcia-Pinillos F 

PROVIDER: S-EPMC6759187 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

Agreement between the spatiotemporal gait parameters from two different wearable devices and high-speed video analysis.

García-Pinillos Felipe F   Latorre-Román Pedro Á PÁ   Soto-Hermoso Víctor M VM   Párraga-Montilla Juan A JA   Pantoja-Vallejo Antonio A   Ramírez-Campillo Rodrigo R   Roche-Seruendo Luis E LE  

PloS one 20190924 9


This study aimed to evaluate the concurrent validity of two different inertial measurement units for measuring spatiotemporal parameters during running on a treadmill, by comparing data with a high-speed video analysis (VA) at 1,000 Hz. Forty-nine endurance runners performed a running protocol on a treadmill at comfortable velocity (i.e., 3.25 ± 0.36 m.s-1). Those wearable devices (i.e., Stryd™ and RunScribe™ systems) were compared to a high-speed VA, as a reference system for measuring spatiote  ...[more]

Similar Datasets

| S-EPMC9474518 | biostudies-literature
| S-EPMC5636070 | biostudies-literature
| S-EPMC8360352 | biostudies-literature
| S-EPMC7412458 | biostudies-literature
| S-EPMC10808505 | biostudies-literature
| S-EPMC7563510 | biostudies-literature
| S-EPMC3766030 | biostudies-other
| S-EPMC5540886 | biostudies-literature
| S-EPMC10548085 | biostudies-literature
| S-EPMC8099131 | biostudies-literature