Unknown

Dataset Information

0

Utility of qSOFA and modified SOFA in severe malaria presenting as sepsis.


ABSTRACT: Sepsis can be caused by malaria infection, but little is known about the utility of the quick Sequential (Sepsis-Related) Organ Failure Assessment (qSOFA) and SOFA score in malaria. We conducted a prospective observational study from March 2013 to February 2017 to examine adults admitted with community-acquired infection in a tertiary-care hospital in Ubon Ratchathani, Northeast Thailand (Ubon-sepsis). Subjects were classified as having sepsis if they had a modified SOFA score ?2 within 24 hours of admission. Serum was stored and later tested for malaria parasites using a nested PCR assay. Presence of severe malaria was defined using modified World Health Organization criteria. Of 4,989 patients enrolled, 153 patients (3%) were PCR positive for either Plasmodium falciparum (74 [48%]), P. vivax (69 [45%]), or both organisms (10 [7%]). Of 153 malaria patients, 80 were severe malaria patients presenting with sepsis, 70 were non-severe malaria patients presenting with sepsis, and three were non-severe malaria patients presenting without sepsis. The modified SOFA score (median 5; IQR 4-6; range 1-18) was strongly correlated with malaria severity determined by the number of World Health Organization severity criteria satisfied by the patient (Spearman's rho = 0.61, p<0.001). Of 80 severe malaria patients, 2 (2.5%), 11 (14%), 62 (77.5%) and 5 (6%), presented with qSOFA scores of 0, 1, 2 and 3, respectively. Twenty eight-day mortality was 1.3% (2/153). In conclusion, qSOFA and SOFA can serve as markers of disease severity in adults with malarial sepsis. Patients presenting with a qSOFA score of 1 may also require careful evaluation for sepsis; including diagnosis of cause of infection, initiation of medical intervention, and consideration for referral as appropriate.

SUBMITTER: Teparrukkul P 

PROVIDER: S-EPMC6785116 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications


Sepsis can be caused by malaria infection, but little is known about the utility of the quick Sequential (Sepsis-Related) Organ Failure Assessment (qSOFA) and SOFA score in malaria. We conducted a prospective observational study from March 2013 to February 2017 to examine adults admitted with community-acquired infection in a tertiary-care hospital in Ubon Ratchathani, Northeast Thailand (Ubon-sepsis). Subjects were classified as having sepsis if they had a modified SOFA score ≥2 within 24 hours  ...[more]

Similar Datasets

| S-EPMC6157867 | biostudies-literature
| S-EPMC6571275 | biostudies-literature