Unknown

Dataset Information

0

Progression characteristics of ellipsoid zone loss in macular telangiectasia type 2.


ABSTRACT: PURPOSE:To investigate the progression characteristics of ellipsoid zone (EZ) loss in eyes with macular telangiectasia type 2 (MacTel) as reflected by area and linear measurements, and their relevance for visual acuity. METHODS:Participants were selected from the MacTel Study cohort. Linear and area measurements of EZ loss were performed in Spectral-Domain Optical Coherence Tomograph (SD-OCT) volume scans. Progression characteristics and correlations between linear and area measurements were analysed using linear mixed effects models. RESULTS:A total of 134 eyes of 70 patients were included (85 eyes with follow-up, mean 4.7 years, range: 1.4-8 years). Ellipsoid zone (EZ) loss significantly progressed at a mean annual increment of 0.057 mm2 (p = 0.005). The progression rate was non-linear and interacted significantly with initial EZ lesion size indicating an exponential growth before reaching a plateau. There was a strong heterogeneity in area sizes between fellow eyes. EZ break length had a significant linear effect on EZ break area (b = 1.06, p < 0.001) and could predict it. The location of the EZ break had a significant impact on visual acuity. CONCLUSION:Ellipsoid zone (EZ) loss in MacTel has a non-linear progression characteristic, and its rate depends on area size at baseline, which must be taken into account at sample selection in clinical trials. Our results show a good correlation of linear and area measures of EZ loss and a segregation of best-corrected visual acuity by EZ location, which may help routine clinical practice.

SUBMITTER: Pauleikhoff D 

PROVIDER: S-EPMC6785352 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Purpose</h4>To investigate the progression characteristics of ellipsoid zone (EZ) loss in eyes with macular telangiectasia type 2 (MacTel) as reflected by area and linear measurements, and their relevance for visual acuity.<h4>Methods</h4>Participants were selected from the MacTel Study cohort. Linear and area measurements of EZ loss were performed in Spectral-Domain Optical Coherence Tomograph (SD-OCT) volume scans. Progression characteristics and correlations between linear and area measur  ...[more]

Similar Datasets

| S-EPMC10362918 | biostudies-literature
| S-EPMC6024664 | biostudies-literature
| S-EPMC6816569 | biostudies-literature
| S-EPMC6154208 | biostudies-literature
| S-EPMC5726940 | biostudies-other
| S-EPMC3638089 | biostudies-literature
| S-EPMC8589180 | biostudies-literature
| S-EPMC7396175 | biostudies-literature
| S-EPMC7538897 | biostudies-literature
| S-EPMC6514016 | biostudies-literature