Unknown

Dataset Information

0

Validation of a New Point Shear-Wave Elastography Method for Noninvasive Assessment of Liver Fibrosis: A Prospective Multicenter Study.


ABSTRACT: OBJECTIVE:To validate the diagnostic value of a new point shear-wave elastography method, S-shearwave elastography (S-SWE; Samsung Medison Co., Ltd.), in noninvasive assessment of liver fibrosis. MATERIALS AND METHODS:In this prospective multicenter study, liver stiffness (LS) measurements for 600 participants were obtained with both S-SWE and transient elastography (TE). The rates of unsuccessful LS measurements in S-SWE and TE were compared, and correlations between S-SWE and TE measurements were assessed. In 107 patients with histologic reference data, the optimal LS cut-off values for predicting severe fibrosis and cirrhosis on S-SWE were determined using receiver operating characteristic (ROC) curve analysis. The LS cut-off values in S-SWE were then validated in 463 patients without histologic reference data by using TE values as the reference standard, and the sensitivity and specificity of the cut-off values for predicting severe fibrosis and cirrhosis were calculated. RESULTS:The frequency of unsuccessful LS measurements on TE (4.5%, 27/600) was significantly higher than that (0.7%, 4/600) on S-SWE (p < 0.001). LS measurements on S-SWE showed a significant correlation with TE values (r = 0.880, p < 0.001). In 107 patients with histological reference data, the areas under the ROC curves on S-SWE were 0.845 and 0.850, with optimal cut-offs of 7.0 kilopascals (kPa) and 9.7 kPa, for the diagnosis of severe fibrosis and cirrhosis, respectively. Using these cut-off values, S-SWE showed sensitivities of 92.9% and 97.4% and specificities of 89.5% and 83.1% in TE-based evaluations of severe fibrosis and cirrhosis, respectively. CONCLUSION:LS measurements on S-SWE were well correlated with those on TE. In addition, S-SWE provided good diagnostic performance for staging of hepatic fibrosis, with a lower rate of unsuccessful LS measurements compared with TE.

SUBMITTER: Joo I 

PROVIDER: S-EPMC6791814 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of a New Point Shear-Wave Elastography Method for Noninvasive Assessment of Liver Fibrosis: A Prospective Multicenter Study.

Joo Ijin I   Kim So Yeon SY   Park Hee Sun HS   Lee Eun Sun ES   Kang Hyo Jeong HJ   Lee Jeong Min JM  

Korean journal of radiology 20191101 11


<h4>Objective</h4>To validate the diagnostic value of a new point shear-wave elastography method, S-shearwave elastography (S-SWE; Samsung Medison Co., Ltd.), in noninvasive assessment of liver fibrosis.<h4>Materials and methods</h4>In this prospective multicenter study, liver stiffness (LS) measurements for 600 participants were obtained with both S-SWE and transient elastography (TE). The rates of unsuccessful LS measurements in S-SWE and TE were compared, and correlations between S-SWE and TE  ...[more]

Similar Datasets

| S-EPMC10063334 | biostudies-literature
| S-EPMC8040233 | biostudies-literature
| S-EPMC9894488 | biostudies-literature
| S-EPMC10102744 | biostudies-literature
| S-EPMC6411150 | biostudies-literature
| S-EPMC11250422 | biostudies-literature
| S-EPMC7483774 | biostudies-literature
| S-EPMC9311739 | biostudies-literature
| S-EPMC6112406 | biostudies-literature
| S-EPMC10555684 | biostudies-literature