An MRI-Compatible Foot-Sole Stimulation System Enabling Characterization of the Brain Response to Walking-Related Tactile Stimuli.


ABSTRACT: Foot-sole somatosensory impairment is a main contributor to balance decline and falls in aging and disease. The cortical networks involved in walking-related foot sole somatosensation, however, remain poorly understood. We thus created and tested a novel MRI-compatible device to enable study of the cortical response to pressure stimuli applied to the foot sole that mimic those stimuli experienced when walking. The device consists of a dual-drive stimulator equipped with two pneumatic cylinders, which are separately programed to apply pressure waveforms to the entire foot sole. In a sample of nine healthy younger adults, the pressure curve applied to the foot sole closely correlated with that experienced during over ground walking (r = 0.811 ± 0.043, P < 0.01). MRI compatibility testing indicated that the device has no or negligible impact on MR image quality. Gradient-recalled echo-planar images of nine healthy young adults using a block-designed 3.5-min walking-related stimulation revealed significant activation within the supplementary motor area, supramarginal gyrus, paracingulate gyri, insula, precentral gyrus, middle temporal gyrus, and hippocampus (uncorrected P < 0.001, k ? 10). Together, these results indicate that this stimulation system is MRI-compatible and capable of mimicking walking-related pressure waveforms on foot sole. It may thus be used as a research tool to identify cortical targets for interventions (e.g., non-invasive brain stimulation) aimed at enhancing this important source of input to the locomotor control system.

SUBMITTER: Zhang T 

PROVIDER: S-EPMC6811610 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

An MRI-Compatible Foot-Sole Stimulation System Enabling Characterization of the Brain Response to Walking-Related Tactile Stimuli.

Zhang Tingwei T   Zhang Kai K   Zhou Junhong J   Chai Yufeng Y   Long Yunfei Y   Wang Xiaoying X   Manor Brad B   Zhang Jue J   Fang Jing J  

Frontiers in neuroscience 20191017


Foot-sole somatosensory impairment is a main contributor to balance decline and falls in aging and disease. The cortical networks involved in walking-related foot sole somatosensation, however, remain poorly understood. We thus created and tested a novel MRI-compatible device to enable study of the cortical response to pressure stimuli applied to the foot sole that mimic those stimuli experienced when walking. The device consists of a dual-drive stimulator equipped with two pneumatic cylinders,  ...[more]

Similar Datasets

| S-EPMC3427509 | biostudies-literature
| S-EPMC9829801 | biostudies-literature
| S-EPMC7426433 | biostudies-literature
| S-EPMC7584726 | biostudies-literature
| S-EPMC4306508 | biostudies-other
| S-EPMC5809529 | biostudies-literature
| S-EPMC8024994 | biostudies-literature
| S-EPMC6593280 | biostudies-literature
| S-EPMC7260196 | biostudies-literature
| S-EPMC8175693 | biostudies-literature