QuEChERS extraction coupled to GC-MS for a fast determination of polychlorinated biphenyls in breast milk from Polish women.


ABSTRACT: Polychlorinated biphenyls (PCBs) in breast milk has been determined. Therefore, it was necessary to develop and adapt an analytical method to analyze PCB compounds. The whole procedure was applied to 31 breast milk samples, which were collected from Polish mothers. The QuEChERS method was optimized as a fast and cheap sample preparation method. The procedure allowed us to obtain recovery values between 96.46% and 119.98% with acceptable relative standard deviations (3.36-12.71%). Gas chromatography with mass spectrometry (GC-MS) was used for final determination. The method was validated using parameters such as linearity, limit of detection and quantification, intra-day precision, and reproducibility. The mean concentration of ?iPCBs in this study was 30.94 ng/g of lipid. Assigned daily intake of PCBs was lower than the tolerable daily intake, which shows that the analyzed milk is safe to the infants. However, the monitoring of PCBs in milk is still important, and the QuEChERS method with GC-MS can be an effective tool for tracking organic impurities in breast milk.

SUBMITTER: Pajewska-Szmyt M 

PROVIDER: S-EPMC6828831 | biostudies-literature | 2019 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

QuEChERS extraction coupled to GC-MS for a fast determination of polychlorinated biphenyls in breast milk from Polish women.

Pajewska-Szmyt Martyna M   Sinkiewicz-Darol Elena E   Bernatowicz-Łojko Urszula U   Kowalkowski Tomasz T   Gadzała-Kopciuch Renata R   Buszewski Bogusław B  

Environmental science and pollution research international 20190826 30


Polychlorinated biphenyls (PCBs) in breast milk has been determined. Therefore, it was necessary to develop and adapt an analytical method to analyze PCB compounds. The whole procedure was applied to 31 breast milk samples, which were collected from Polish mothers. The QuEChERS method was optimized as a fast and cheap sample preparation method. The procedure allowed us to obtain recovery values between 96.46% and 119.98% with acceptable relative standard deviations (3.36-12.71%). Gas chromatogra  ...[more]

Similar Datasets

| S-EPMC9743266 | biostudies-literature
| S-EPMC10487233 | biostudies-literature
| S-EPMC6345796 | biostudies-literature
| S-EPMC10486934 | biostudies-literature
| S-EPMC10254206 | biostudies-literature
| S-EPMC6384567 | biostudies-literature
| S-EPMC8047638 | biostudies-literature
| S-EPMC7759298 | biostudies-literature
| S-EPMC6262625 | biostudies-literature
| S-EPMC8536010 | biostudies-literature