Unknown

Dataset Information

0

Evaluation of a human glycated hemoglobin test in canine diabetes mellitus.


ABSTRACT: Glycated hemoglobin A1c (HbA1c) is widely used for monitoring and diagnosing human diabetes mellitus, but is rarely used in veterinary clinics. The goal of our study was to validate the commercial HbA1c testing system SD A1cCare analyzer (Bionote, Gyeoggi-do, South Korea) for use in dogs. Dogs were recruited with owner's consent. Diabetic status was determined based on clinical signs, fasting hyperglycemia, and glycosuria. Intra-assay precision and linearity were evaluated with EDTA, heparin, or citrate as anticoagulants, and had excellent precision with mean coefficients of variation (CVs) of 2.47%, 2.26%, and 1.92%, respectively. Diluted anticoagulated blood samples showed excellent linear relationships with R2 of 0.991, 0.996, and 0.994, respectively. Inter-assay precision revealed that the mean CV of the normal control was 2.18% and that of the high control was 2.01% (30 repeats). Observed total error of a normal control was 7.81%, and 6.12% for the high control. HbA1c level measured before and after removal of plasma and replacement by saline showed minimal interference by lipid contents ( p = 0.929). The HbA1c concentrations of diabetic dogs were significantly higher than those of non-diabetic dogs ( p < 0.001). HbA1c value >6.2% indicated canine diabetes through a classification and regression tree model. In most cases, fructosamine and HbA1c were highly correlated ( r = 0.674, p < 0.001). The HbA1c testing system could be a valuable testing system to evaluate canine diabetes mellitus, providing an alternative in-house option for use by veterinary clinicians.

SUBMITTER: Kim NY 

PROVIDER: S-EPMC6838714 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of a human glycated hemoglobin test in canine diabetes mellitus.

Kim Na-Yon NY   An Jaehoon J   Jeong Jae-Kyung JK   Ji Sumin S   Hwang Sung-Hyun SH   Lee Hong-Seok HS   Kim Myung-Chul MC   Kim Hyun-Wook HW   Won Sungho S   Kim Yongbaek Y  

Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc 20190218 3


Glycated hemoglobin A1c (HbA1c) is widely used for monitoring and diagnosing human diabetes mellitus, but is rarely used in veterinary clinics. The goal of our study was to validate the commercial HbA1c testing system SD A1cCare analyzer (Bionote, Gyeoggi-do, South Korea) for use in dogs. Dogs were recruited with owner's consent. Diabetic status was determined based on clinical signs, fasting hyperglycemia, and glycosuria. Intra-assay precision and linearity were evaluated with EDTA, heparin, or  ...[more]

Similar Datasets

| S-EPMC5860385 | biostudies-literature
| S-EPMC7803600 | biostudies-literature
| S-EPMC7929744 | biostudies-literature
| S-EPMC2872990 | biostudies-literature
| S-EPMC6425874 | biostudies-literature
| S-EPMC5370432 | biostudies-literature
| S-EPMC3521136 | biostudies-literature
| S-EPMC4713060 | biostudies-literature
| S-EPMC5754373 | biostudies-literature
| S-EPMC6981558 | biostudies-literature