The difficulty of diagnosing NCSE in clinical practice; external validation of the Salzburg criteria.
Ontology highlight
ABSTRACT: To improve the diagnostic accuracy of electroencephalography (EEG) criteria for nonconvulsive status epilepticus (NCSE), external validation of the recently proposed Salzburg criteria is paramount. We performed an external, retrospective, diagnostic accuracy study of the Salzburg criteria, using EEG recordings from patients with and without a clinical suspicion of having NCSE. Of the 191 EEG recordings, 12 (12%) was classified as an NCSE according to the reference standard. In the validation cohort, sensitivity was 67% and specificity was 89%. The positive predictive value was 47% and the negative predictive value was 95%. Ten patients in the control group (n = 93) were false positive, resulting in a specificity of 89.2%. The interrater agreement between the reference standards and between
SUBMITTER: Goselink RJM
PROVIDER: S-EPMC6852511 | biostudies-literature | 2019 Aug
REPOSITORIES: biostudies-literature