Potentiometric sensor for iron (III) quantitative determination: experimental and computational approaches.


ABSTRACT: The current work deals with fabrication and validation of a new highly Fe3+ selective sensor based on benzo-18-crown-6 (b-18C6) using the potentiometric method. The proposed sensor revealed satisfactory performance for quantitative evaluation of Fe3+ trace amount in environmental samples. The ratio of membrane ingredients optimized and the membrane with the composition of 4:30:65.5:0.5 mg of b-18C6:PVC:o-NPOE:KTpClPB exhibited the desirable Nernstian slope of 19.51?±?0.10 (mV per decade of activity) over the pH range from 2.5 to 5.7 with an acceptable dynamic concentration range of 1.0?×?10-6 M to 1.0?×?10-1 M and lower detection limit of 8.0?×?10-7 M. The proposed sensor demonstrated an appropriate reproducibility with a rapid response time of 12 s and the suitable lifetime of 10 weeks. To validate the accurate response of the proposed sensor, AAS technique applied for the determination of Fe3+ in real aqueous mediums such as drinking tap water and hospital wastewater sample after treatment by electrocoagulation process. Theoretical studies carried out using DFT/B3LYP computational level with 6-311G basis set to optimize the adsorption sites of Fe+3 cationic species by b-18C6. The obtained adsorption energy with large negative value confirmed the formation of a stable complex.

SUBMITTER: Badakhshan S 

PROVIDER: S-EPMC6859631 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Potentiometric sensor for iron (III) quantitative determination: experimental and computational approaches.

Badakhshan Somayeh S   Ahmadzadeh Saeid S   Mohseni-Bandpei Anoushiravan A   Aghasi Majid M   Basiri Amir A  

BMC chemistry 20191118 1


The current work deals with fabrication and validation of a new highly Fe<sup>3+</sup> selective sensor based on benzo-18-crown-6 (b-18C6) using the potentiometric method. The proposed sensor revealed satisfactory performance for quantitative evaluation of Fe<sup>3+</sup> trace amount in environmental samples. The ratio of membrane ingredients optimized and the membrane with the composition of 4:30:65.5:0.5 mg of b-18C6:PVC:o-NPOE:KTpClPB exhibited the desirable Nernstian slope of 19.51 ± 0.10 (  ...[more]

Similar Datasets

| S-EPMC8623495 | biostudies-literature
| S-EPMC8434286 | biostudies-literature
| S-EPMC8482224 | biostudies-literature
| S-EPMC3265130 | biostudies-literature
| S-EPMC4513347 | biostudies-literature
| S-EPMC8621773 | biostudies-literature
| S-EPMC2998235 | biostudies-literature
| S-EPMC8695446 | biostudies-literature
| S-EPMC4497327 | biostudies-literature
| S-EPMC9316631 | biostudies-literature