Unknown

Dataset Information

0

Patient specific hemodynamic response functions associated with interictal discharges recorded via simultaneous intracranial EEG-fMRI.


ABSTRACT: Simultaneous collection of scalp EEG and fMRI has become an important tool for studying the hemodynamic changes associated with interictal epileptiform discharges (IEDs) in persons with epilepsy, and has become a standard presurgical assessment tool in some centres. We previously demonstrated that performing EEG-fMRI using intracranial electrodes (iEEG-fMRI) is of low risk to patients in our research centre, and offers unique insight into BOLD signal changes associated with IEDs recorded from very discrete sources. However, it is unknown whether the BOLD response corresponding to IEDs recorded by iEEG-fMRI follows the canonical hemodynamic response. We therefore scanned 11 presurgical epilepsy patients using iEEG-fMRI, and assessed the hemodynamic response associated with individual IEDs using two methods: assessment of BOLD signal changes associated with isolated IEDs at the location of the active intracranial electrode, and by estimating subject-specific impulse response functions to isolated IEDs. We found that the hemodynamic response associated with the intracranially recorded discharges varied by patient and by spike location. The observed shape and timing differences also deviated from the canonical hemodynamic response function traditionally used in many fMRI experiments. It is recommended that future iEEG-fMRI studies of IEDs use a flexible hemodynamic response model when performing parametric tests to accurately characterize these data.

SUBMITTER: Beers CA 

PROVIDER: S-EPMC6869833 | biostudies-literature | 2015 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Patient specific hemodynamic response functions associated with interictal discharges recorded via simultaneous intracranial EEG-fMRI.

Beers Craig A CA   Williams Rebecca J RJ   Gaxiola-Valdez Ismael I   Pittman Daniel J DJ   Kang Anita T AT   Aghakhani Yahya Y   Pike G Bruce GB   Goodyear Bradley G BG   Federico Paolo P  

Human brain mapping 20150929 12


Simultaneous collection of scalp EEG and fMRI has become an important tool for studying the hemodynamic changes associated with interictal epileptiform discharges (IEDs) in persons with epilepsy, and has become a standard presurgical assessment tool in some centres. We previously demonstrated that performing EEG-fMRI using intracranial electrodes (iEEG-fMRI) is of low risk to patients in our research centre, and offers unique insight into BOLD signal changes associated with IEDs recorded from ve  ...[more]

Similar Datasets

| S-EPMC4801878 | biostudies-literature
| S-EPMC8490636 | biostudies-literature
| S-EPMC8312480 | biostudies-literature
| S-EPMC6861611 | biostudies-literature
| S-EPMC6861611 | biostudies-literature
| S-EPMC6861611 | biostudies-literature
| S-EPMC4832091 | biostudies-literature
| S-EPMC7784722 | biostudies-literature
| S-EPMC7062638 | biostudies-literature