Unknown

Dataset Information

0

Cluster analysis of time evolution (CAT) for quantitative susceptibility mapping (QSM) and quantitative blood oxygen level-dependent magnitude (qBOLD)-based oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) mapping.


ABSTRACT:

Purpose

To improve the accuracy of QSM plus quantitative blood oxygen level-dependent magnitude (QSM + qBOLD or QQ)-based mapping of the oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) using cluster analysis of time evolution (CAT).

Methods

3D multi-echo gradient echo and arterial spin labeling images were acquired in 11 healthy subjects and 5 ischemic stroke patients. DWI was also carried out on patients. CAT was developed for analyzing signal evolution over TE. QQ-based OEF and CMRO2 were reconstructed with and without CAT, and results were compared using region of interest analysis and a paired t-test.

Results

Simulations demonstrated that CAT substantially reduced noise error in QQ-based OEF. In healthy subjects, QQ-based OEF appeared less noisy and more uniform with CAT than without CAT; average OEF with and without CAT in cortical gray matter was 32.7 ± 4.0% and 37.9 ± 4.5%, with corresponding CMRO2 of 148.4 ± 23.8 and 171.4 ± 22.4 ?mol/100 g/min, respectively. In patients, regions of low OEF were confined within the ischemic lesions defined on DWI when using CAT, which was not observed without CAT.

Conclusion

The cluster analysis of time evolution (CAT) significantly improves the robustness of QQ-based OEF against noise.

SUBMITTER: Cho J 

PROVIDER: S-EPMC6879790 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cluster analysis of time evolution (CAT) for quantitative susceptibility mapping (QSM) and quantitative blood oxygen level-dependent magnitude (qBOLD)-based oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO<sub>2</sub> ) mapping.

Cho Junghun J   Zhang Shun S   Kee Youngwook Y   Spincemaille Pascal P   Nguyen Thanh D TD   Hubertus Simon S   Gupta Ajay A   Wang Yi Y  

Magnetic resonance in medicine 20190910 3


<h4>Purpose</h4>To improve the accuracy of QSM plus quantitative blood oxygen level-dependent magnitude (QSM + qBOLD or QQ)-based mapping of the oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO<sub>2</sub> ) using cluster analysis of time evolution (CAT).<h4>Methods</h4>3D multi-echo gradient echo and arterial spin labeling images were acquired in 11 healthy subjects and 5 ischemic stroke patients. DWI was also carried out on patients. CAT was developed for analyzing  ...[more]

Similar Datasets

| S-EPMC6097883 | biostudies-literature
| S-EPMC9133659 | biostudies-literature
| S-EPMC8221765 | biostudies-literature
| S-EPMC6503182 | biostudies-literature
| S-EPMC7722021 | biostudies-literature
| S-EPMC3836742 | biostudies-literature
| S-EPMC7613100 | biostudies-literature
| S-EPMC7528217 | biostudies-literature
| S-EPMC8720043 | biostudies-literature
| S-EPMC4874185 | biostudies-literature