Initial clinical evaluation of stationary digital chest tomosynthesis in adult patients with cystic fibrosis.


ABSTRACT: OBJECTIVE:The imaging evaluation of cystic fibrosis currently relies on chest radiography or computed tomography. Recently, digital chest tomosynthesis has been proposed as an alternative. We have developed a stationary digital chest tomosynthesis (s-DCT) system based on a carbon nanotube (CNT) linear x-ray source array. This system enables tomographic imaging without movement of the x-ray tube and allows for physiological gating. The goal of this study was to evaluate the feasibility of clinical CF imaging with the s-DCT system. MATERIALS AND METHODS:CF patients undergoing clinically indicated chest radiography were recruited for the study and imaged on the s-DCT system. Three board-certified radiologists reviewed both the CXR and s-DCT images for image quality relevant to CF. CF disease severity was assessed by Brasfield score on CXR and chest tomosynthesis score on s-DCT. Disease severity measures were also evaluated against subject pulmonary function tests. RESULTS:Fourteen patients underwent s-DCT imaging within 72 h of their chest radiograph imaging. Readers scored the visualization of proximal bronchi, small airways and vascular pattern higher on s-DCT than CXR. Correlation between the averaged Brasfield score and averaged tomosynthesis disease severity score for CF was -0.73, p = 0.0033. The CF disease severity score system for tomosynthesis had high correlation with FEV1 (r = -0.685) and FEF 25-75% (r = -0.719) as well as good correlation with FVC (r = -0.582). CONCLUSION:We demonstrate the potential of CNT x-ray-based s-DCT for use in the evaluation of cystic fibrosis disease status in the first clinical study of s-DCT. KEY POINTS:• Carbon nanotube-based linear array x-ray tomosynthesis systems have the potential to provide diagnostically relevant information for patients with cystic fibrosis without the need for a moving gantry. • Despite the short angular span in this prototype system, lung features such as the proximal bronchi, small airways and pulmonary vasculature have improved visualization on s-DCT compared with CXR. Further improvements are anticipated with longer linear x-ray array tubes. • Evaluation of disease severity in CF patients is possible with s-DCT, yielding improved visualization of important lung features and high correlation with pulmonary function tests at a relatively low dose.

SUBMITTER: Gunnell ET 

PROVIDER: S-EPMC6896210 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Initial clinical evaluation of stationary digital chest tomosynthesis in adult patients with cystic fibrosis.

Gunnell Elias Taylor ET   Franceschi Dora K DK   Inscoe Christina R CR   Hartman Allison A   Goralski Jennifer L JL   Ceppe Agathe A   Handly Brian B   Sams Cassandra C   Fordham Lynn Ansley LA   Lu Jianping J   Zhou Otto O   Lee Yueh Z YZ  

European radiology 20180925 4


<h4>Objective</h4>The imaging evaluation of cystic fibrosis currently relies on chest radiography or computed tomography. Recently, digital chest tomosynthesis has been proposed as an alternative. We have developed a stationary digital chest tomosynthesis (s-DCT) system based on a carbon nanotube (CNT) linear x-ray source array. This system enables tomographic imaging without movement of the x-ray tube and allows for physiological gating. The goal of this study was to evaluate the feasibility of  ...[more]

Similar Datasets

| S-EPMC6635094 | biostudies-literature
| S-EPMC8902128 | biostudies-literature
| S-EPMC6237281 | biostudies-literature
| S-EPMC3267795 | biostudies-other
| S-EPMC10027634 | biostudies-literature
| S-EPMC3146055 | biostudies-other
| S-EPMC5207128 | biostudies-literature
| S-EPMC4378917 | biostudies-literature
| S-EPMC4319526 | biostudies-literature
| S-EPMC3321055 | biostudies-other