Unknown

Dataset Information

0

Accuracy and incremental yield of urine Xpert MTB/RIF Ultra versus Determine TB-LAM for diagnosis of pulmonary tuberculosis.


ABSTRACT: The performance of urine Xpert MTB/RIF Ultra (Xpert Ultra) for pulmonary TB diagnosis is unknown. HIV-positive and HIV-negative adults were enrolled at two health facilities in Kampala, Uganda. We compared the accuracy of urine Xpert Ultra and Determine TB-LAM in reference to sputum-based testing (positive Xpert MTB/RIF or culture), and assessed incremental yield. Urine Xpert Ultra had low sensitivity (17.2%, 95% CI 12.3-23.2) but high specificity (98.1%, 95% CI 94.4-99.6). Sensitivity reached 50.0% (95% CI 28.2-71.8) among HIV-positive patients with CD4 <100 cells/?L. Compared to Determine TB-LAM, urine Xpert Ultra was 9.4% (95% CI 3.8-14.9, P?=?0.01) more sensitive, and 17.2% (95% CI 4.5-29.8, P?=?0.01) more sensitive among HIV-positive patients. However, the incremental sensitivity of urine Xpert Ultra relative to sputum Xpert MTB/RIF was only 1% (95% CI -0.9 to 2.8). Urine Xpert Ultra could be an alternative for patients with advanced HIV infection unable to produce sputum.

SUBMITTER: Andama A 

PROVIDER: S-EPMC6906254 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy and incremental yield of urine Xpert MTB/RIF Ultra versus Determine TB-LAM for diagnosis of pulmonary tuberculosis.

Andama A A   Jaganath D D   Crowder R R   Asege L L   Nakaye M M   Katumba D D   Mwebe S S   Semitala F F   Worodria W W   Joloba M M   Mohanty S S   Somoskovi A A   Cattamanchi A A  

Diagnostic microbiology and infectious disease 20190904 1


The performance of urine Xpert MTB/RIF Ultra (Xpert Ultra) for pulmonary TB diagnosis is unknown. HIV-positive and HIV-negative adults were enrolled at two health facilities in Kampala, Uganda. We compared the accuracy of urine Xpert Ultra and Determine TB-LAM in reference to sputum-based testing (positive Xpert MTB/RIF or culture), and assessed incremental yield. Urine Xpert Ultra had low sensitivity (17.2%, 95% CI 12.3-23.2) but high specificity (98.1%, 95% CI 94.4-99.6). Sensitivity reached 5  ...[more]

Similar Datasets

| S-EPMC9241712 | biostudies-literature
| S-EPMC7192026 | biostudies-literature
| S-EPMC7045088 | biostudies-literature
| S-EPMC9273090 | biostudies-literature
| S-EPMC8709852 | biostudies-literature
| S-EPMC6711687 | biostudies-literature
| S-EPMC6946130 | biostudies-literature
| S-EPMC6170999 | biostudies-literature
| S-EPMC7512177 | biostudies-literature