Unknown

Dataset Information

0

Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study.


ABSTRACT:

Background

Atrial fibrillation is the most common recurrent arrhythmia in clinical practice, with most clinical events occurring outside the hospital. Low detection and nonadherence to guidelines are the primary obstacles to atrial fibrillation management. Photoplethysmography is a novel technology developed for atrial fibrillation screening. However, there has been limited validation of photoplethysmography-based smart devices for the detection of atrial fibrillation and its underlying clinical factors impacting detection.

Objective

This study aimed to explore the feasibility of photoplethysmography-based smart devices for the detection of atrial fibrillation in real-world settings.

Methods

Subjects aged ?18 years (n=361) were recruited from September 14 to October 16, 2018, for screening of atrial fibrillation with active measurement, initiated by the users, using photoplethysmography-based smart wearable devices (ie, a smart band or smart watches). Of these, 200 subjects were also automatically and periodically monitored for 14 days with a smart band. The baseline diagnosis of "suspected" atrial fibrillation was confirmed by electrocardiogram and physical examination. The sensitivity and accuracy of photoplethysmography-based smart devices for monitoring atrial fibrillation were evaluated.

Results

A total of 2353 active measurement signals and 23,864 periodic measurement signals were recorded. Eleven subjects were confirmed to have persistent atrial fibrillation, and 20 were confirmed to have paroxysmal atrial fibrillation. Smart devices demonstrated >91% predictive ability for atrial fibrillation. The sensitivity and specificity of devices in detecting atrial fibrillation among active recording of the 361 subjects were 100% and about 99%, respectively. For subjects with persistent atrial fibrillation, 127 (97.0%) active measurements and 2240 (99.2%) periodic measurements were identified as atrial fibrillation by the algorithm. For subjects with paroxysmal atrial fibrillation, 36 (17%) active measurements and 717 (19.8%) periodic measurements were identified as atrial fibrillation by the algorithm. All persistent atrial fibrillation cases could be detected as "atrial fibrillation episodes" by the photoplethysmography algorithm on the first monitoring day, while 14 (70%) patients with paroxysmal atrial fibrillation demonstrated "atrial fibrillation episodes" within the first 6 days. The average time to detect paroxysmal atrial fibrillation was 2 days (interquartile range: 1.25-5.75) by active measurement and 1 day (interquartile range: 1.00-2.00) by periodic measurement (P=.10). The first detection time of atrial fibrillation burden of <50% per 24 hours was 4 days by active measurement and 2 days by periodic measurementThe first detection time of atrial fibrillation burden of >50% per 24 hours was 1 day for both active and periodic measurements (active measurement: P=.02, periodic measurement: P=.03).

Conclusions

Photoplethysmography-based smart devices demonstrated good atrial fibrillation predictive ability in both active and periodic measurements. However, atrial fibrillation type could impact detection, resulting in increased monitoring time.

Trial registration

Chinese Clinical Trial Registry of the International Clinical Trials Registry Platform of the World Health Organization ChiCTR-OOC-17014138; http://www.chictr.org.cn/showprojen.aspx?proj=24191.

SUBMITTER: Zhang H 

PROVIDER: S-EPMC6918204 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study.

Zhang Hui H   Zhang Jie J   Li Hong-Bao HB   Chen Yi-Xin YX   Yang Bin B   Guo Yu-Tao YT   Chen Yun-Dai YD  

Journal of medical Internet research 20191203 12


<h4>Background</h4>Atrial fibrillation is the most common recurrent arrhythmia in clinical practice, with most clinical events occurring outside the hospital. Low detection and nonadherence to guidelines are the primary obstacles to atrial fibrillation management. Photoplethysmography is a novel technology developed for atrial fibrillation screening. However, there has been limited validation of photoplethysmography-based smart devices for the detection of atrial fibrillation and its underlying  ...[more]

Similar Datasets

| S-EPMC6396075 | biostudies-literature
| S-EPMC8764282 | biostudies-literature
| S-EPMC8038592 | biostudies-literature
| S-EPMC6931792 | biostudies-literature
| S-EPMC10423524 | biostudies-literature
| S-EPMC7521464 | biostudies-literature
| S-EPMC6835966 | biostudies-literature
| S-EPMC10051367 | biostudies-literature
| S-EPMC10455667 | biostudies-literature
| S-EPMC7416615 | biostudies-literature