Unknown

Dataset Information

0

Vessel Density in Glaucoma of Different Entities as Measured with Optical Coherence Tomography Angiography.


ABSTRACT: Purpose:To compare papillary and macular vessel density (VD), as measured by optical coherence tomography angiography (OCTA), in eyes with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG) and exfoliation glaucoma (XFG). Methods:The papillary and macular VD of 40 eyes with POAG, 19 with NTG and 21 with XFG were examined using OCTA (AngioVue™). The VD was measured at two different layers of segmentation (optic nerve head: radial peripapillary capillary [RPC] and nerve head [NH]; macula: superficial [SL] and deep [DL] retinal vascular plexus) with a 4.5×4.5mm papillary and 6×6-mm macular scan. VD was calculated by an automated density measuring tool in the AngioVue™ software. Results:There were no significant differences in the total value of the papillary, peripapillary and macular VD. A significantly higher VD could be measured for NTG compared to POAG, as well as for XFG in the inferior nasal peripapillary sector at RPC-segmentation and at the NH-level between NDG and XFG. Conclusion:OCTA can detect a difference in VD in the nasal inferior peripapillary sector in NTG compared with POAG and XFG. These findings may help to improve the understanding of further pathophysiological mechanisms.

SUBMITTER: Lommatzsch C 

PROVIDER: S-EPMC6925548 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

Vessel Density in Glaucoma of Different Entities as Measured with Optical Coherence Tomography Angiography.

Lommatzsch C C   Rothaus K K   Koch J M JM   Heinz C C   Grisanti S S  

Clinical ophthalmology (Auckland, N.Z.) 20191217


<h4>Purpose</h4>To compare papillary and macular vessel density (VD), as measured by optical coherence tomography angiography (OCTA), in eyes with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG) and exfoliation glaucoma (XFG).<h4>Methods</h4>The papillary and macular VD of 40 eyes with POAG, 19 with NTG and 21 with XFG were examined using OCTA (AngioVue™). The VD was measured at two different layers of segmentation (optic nerve head: radial peripapillary capillary [RPC] and ner  ...[more]

Similar Datasets

| S-EPMC7422875 | biostudies-literature
| S-EPMC8361292 | biostudies-literature
| S-EPMC10042115 | biostudies-literature
| S-EPMC7033250 | biostudies-literature
| S-EPMC7576041 | biostudies-literature
| S-EPMC6567835 | biostudies-literature
| S-EPMC5970064 | biostudies-literature
| S-EPMC5289421 | biostudies-literature
| S-EPMC5880710 | biostudies-literature
| S-EPMC5650189 | biostudies-literature