Unknown

Dataset Information

0

The role of gadolinium in magnetic resonance imaging for early prostate cancer diagnosis: A diagnostic accuracy study.


ABSTRACT:

Objective

Prostate lesions detected with multiparametric magnetic resonance imaging (mpMRI) are classified for their malignant potential according to the Prostate Imaging-Reporting And Data System (PI-RADS™2). In this study, we evaluate the diagnostic accuracy of the mpMRI with and without gadolinium, with emphasis on the added diagnostic value of the dynamic contrast enhancement (DCE).

Materials and methods

The study was retrospective for 286 prostate lesions / 213 eligible patients, n = 116/170, and 49/59% malignant for the peripheral (Pz) and transitional zone (Tz), respectively. A stereotactic MRI-guided prostate biopsy served as the histological ground truth. All patients received a mpMRI with DCE. The influence of DCE in the prediction of malignancy was analyzed by blinded assessment of the imaging protocol without DCE and the DCE separately.

Results

Significant (CSPca) and insignificant (IPca) prostate cancers were evaluated separately to enhance the potential effects of the DCE in the detection of CSPca. The Receiver Operating Characteristics Area Under Curve (ROC-AUC), sensitivity (Se) and specificity (Spe) of PIRADS-without-DCE in the Pz was 0.70/0.47/0.86 for all cancers (IPca and CSPca merged) and 0.73/0.54/0.82 for CSPca. PIRADS-with-DCE for the same patients showed ROC-AUC/Se/Spe of 0.70/0.49/0.86 for all Pz cancers and 0.69/0.54/0.81 for CSPca in the Pz, respectively, p>0.05 chi-squared test. Similar results for the Tz, AUC/Se/Spe for PIRADS-without-DCE was 0.75/0.61/0.79 all cancers and 0.67/0.54/0.71 for CSPca, not influenced by DCE (0.66/0.47/0.81 for all Tz cancers and 0.61/0.39/0.75 for CSPca in Tz). The added Se and Spe of DCE for the detection of CSPca was 88/34% and 78/33% in the Pz and Tz, respectively.

Conclusion

DCE showed no significant added diagnostic value and lower specificity for the prediction of CSPca compared to the non-enhanced sequences. Our results support that gadolinium might be omitted without mitigating the diagnostic accuracy of the mpMRI for prostate cancer.

SUBMITTER: Cosma I 

PROVIDER: S-EPMC6927639 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

The role of gadolinium in magnetic resonance imaging for early prostate cancer diagnosis: A diagnostic accuracy study.

Cosma Ilinca I   Tennstedt-Schenk Cornelia C   Winzler Sven S   Psychogios Marios Nikos MN   Pfeil Alexander A   Teichgraeber Ulf U   Malich Ansgar A   Papageorgiou Ismini I  

PloS one 20191223 12


<h4>Objective</h4>Prostate lesions detected with multiparametric magnetic resonance imaging (mpMRI) are classified for their malignant potential according to the Prostate Imaging-Reporting And Data System (PI-RADS™2). In this study, we evaluate the diagnostic accuracy of the mpMRI with and without gadolinium, with emphasis on the added diagnostic value of the dynamic contrast enhancement (DCE).<h4>Materials and methods</h4>The study was retrospective for 286 prostate lesions / 213 eligible patie  ...[more]

Similar Datasets

| S-EPMC7373864 | biostudies-literature
| S-EPMC8507636 | biostudies-literature
| S-EPMC5443513 | biostudies-literature
| S-EPMC8885602 | biostudies-literature
| S-EPMC10110999 | biostudies-literature
| S-EPMC5652829 | biostudies-literature
| S-EPMC8350232 | biostudies-literature
| S-EPMC6317805 | biostudies-literature
2018-12-01 | GSE101908 | GEO
| S-EPMC4892988 | biostudies-literature