Unknown

Dataset Information

0

Arthroscopic and Fluoroscopic Guidance Removal of Intratendinous Broken Instrument During Rotator Cuff Repair.


ABSTRACT: Instrument breakage during arthroscopic rotator cuff repair is a rare complication of shoulder arthroscopy, especially when the broken instrument has been left inside the tendon part of the rotator cuff. We propose a combined arthroscopy and fluoroscopic guidance technique to ease the removal of the broken instrument and repair the torn rotator cuff after removal.

SUBMITTER: Prasataporn N 

PROVIDER: S-EPMC6948112 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC3716233 | biostudies-literature
| S-EPMC5496001 | biostudies-literature
| S-EPMC6993199 | biostudies-literature
| S-EPMC9244636 | biostudies-literature
| S-EPMC5040237 | biostudies-literature
| S-EPMC4314554 | biostudies-literature
| S-EPMC5765808 | biostudies-other
| S-EPMC6713816 | biostudies-other
| S-EPMC6609773 | biostudies-literature
| S-EPMC4129987 | biostudies-literature