Unknown

Dataset Information

0

Sepsis surveillance: an examination of parameter sensitivity and alert reliability.


ABSTRACT: Objective:To examine performance of a sepsis surveillance system in a simulated environment where modifications to parameters and settings for identification of at-risk patients can be explored in-depth. Materials and Methods:This was a multiple center observational cohort study. The study population comprised 14 917 adults hospitalized in 2016. An expert-driven rules algorithm was applied against 15.1 million data points to simulate a system with binary notification of sepsis events. Three system scenarios were examined: a scenario as derived from the second version of the Consensus Definitions for Sepsis and Septic Shock (SEP-2), the same scenario but without systolic blood pressure (SBP) decrease criteria (near SEP-2), and a conservative scenario with limited parameters. Patients identified by scenarios as being at-risk for sepsis were assessed for suspected infection. Multivariate binary logistic regression models estimated mortality risk among patients with suspected infection. Results:First, the SEP-2-based scenario had a hyperactive, unreliable parameter SBP decrease >40?mm?Hg from baseline. Second, the near SEP-2 scenario demonstrated adequate reliability and sensitivity. Third, the conservative scenario had modestly higher reliability, but sensitivity degraded quickly. Parameters differed in predicting mortality risk and represented a substitution effect between scenarios. Discussion:Configuration of parameters and alert criteria have implications for patient identification and predicted outcomes. Conclusion:Performance of scenarios was associated with scenario design. A single hyperactive, unreliable parameter may negatively influence adoption of the system. A trade-off between modest improvements in alert reliability corresponded to a steep decline in condition sensitivity in scenarios explored.

SUBMITTER: Amland RC 

PROVIDER: S-EPMC6951868 | biostudies-literature | 2019 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Sepsis surveillance: an examination of parameter sensitivity and alert reliability.

Amland Robert C RC   Burghart Mark M   Overhage J Marc JM  

JAMIA open 20190611 3


<h4>Objective</h4>To examine performance of a sepsis surveillance system in a simulated environment where modifications to parameters and settings for identification of at-risk patients can be explored in-depth.<h4>Materials and methods</h4>This was a multiple center observational cohort study. The study population comprised 14 917 adults hospitalized in 2016. An expert-driven rules algorithm was applied against 15.1 million data points to simulate a system with binary notification of sepsis eve  ...[more]

Similar Datasets

| S-EPMC8746786 | biostudies-literature
| S-EPMC5903599 | biostudies-literature
| S-EPMC4477829 | biostudies-literature
| S-EPMC5505410 | biostudies-other
| S-EPMC4727886 | biostudies-literature
| S-EPMC4642144 | biostudies-literature
| S-EPMC8864844 | biostudies-literature
| S-EPMC9300636 | biostudies-literature
| S-EPMC6860967 | biostudies-literature
| S-EPMC2717232 | biostudies-literature