Matched-Pair Comparison of 68Ga-PSMA-11 PET/CT and 18F-PSMA-1007 PET/CT: Frequency of Pitfalls and Detection Efficacy in Biochemical Recurrence After Radical Prostatectomy.


ABSTRACT: 18F-labeled prostate-specific membrane antigen (PSMA)-ligand PET has several principal advantages over 68Ga-PSMA-11. The purpose of this retrospective study was to evaluate the frequency of non-tumor-related uptake and the detection efficacy comparing 68Ga-PSMA-11 PET/CT and 18F-PSMA-1007 PET/CT in recurrent prostate cancer (PC) patients. Methods: The study included 102 patients with biochemically recurrent PC after radical prostatectomy undergoing 18F-PSMA-1007 PET/CT imaging. On the basis of various clinical variables, patients with corresponding 68Ga-PSMA-11 PET/CT scans were matched. All PET/CT scans (n = 204) were reviewed by 1 nuclear medicine physician. First, all PET-positive lesions were noted. Then, lesions suspected of being recurrent PC were differentiated from lesions attributed to a benign origin on the basis of known pitfalls and information from CT. For each region, the SUVmax of the lesion with the highest PSMA-ligand uptake was noted. Detection rates were determined, and SUVmax was compared separately for 68Ga-PSMA-11 and 18F-PSMA-1007. Results: In total, 18F-PSMA-1007 PET and 68Ga-PSMA-11 PET revealed 369 and 178 PSMA-ligand-positive lesions, respectively. 18F-PSMA-1007 PET revealed approximately 5 times more lesions attributed to a benign origin than did 68Ga-PSMA-11 PET (245 vs. 52 lesions, respectively). The benign lesions most frequently observed were ganglia, unspecific lymph node, and bone lesions, at a rate of 43%, 31%, and 24% for 18F-PSMA-1007 PET and 29%, 42%, and 27% for 68Ga-PSMA-11 PET, respectively. The SUVmax of lesions attributed to a benign origin was significantly higher (P < 0.0001) for 18F-PSMA-1007 PET. Further, a similar number of lesions was attributed to recurrent PC (124/369 for 18F-PSMA-1007 PET and 126/178 for 68Ga-PSMA-11 PET). Conclusion: The number of lesions with increased PSMA-ligand uptake attributed to a benign origin is considerably higher for 18F-PSMA-1007 PET than for 68Ga-PSMA-11 PET. This finding indicates the need for sophisticated reader training emphasizing known pitfalls and reporting within the clinical context.

SUBMITTER: Rauscher I 

PROVIDER: S-EPMC6954457 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Matched-Pair Comparison of <sup>68</sup>Ga-PSMA-11 PET/CT and <sup>18</sup>F-PSMA-1007 PET/CT: Frequency of Pitfalls and Detection Efficacy in Biochemical Recurrence After Radical Prostatectomy.

Rauscher Isabel I   Krönke Markus M   König Michael M   Gafita Andrei A   Maurer Tobias T   Horn Thomas T   Schiller Kilian K   Weber Wolfgang W   Eiber Matthias M  

Journal of nuclear medicine : official publication, Society of Nuclear Medicine 20190628 1


<sup>18</sup>F-labeled prostate-specific membrane antigen (PSMA)-ligand PET has several principal advantages over <sup>68</sup>Ga-PSMA-11. The purpose of this retrospective study was to evaluate the frequency of non-tumor-related uptake and the detection efficacy comparing <sup>68</sup>Ga-PSMA-11 PET/CT and <sup>18</sup>F-PSMA-1007 PET/CT in recurrent prostate cancer (PC) patients. <b>Methods:</b> The study included 102 patients with biochemically recurrent PC after radical prostatectomy undergo  ...[more]

Similar Datasets

| S-EPMC10997563 | biostudies-literature
| S-EPMC5486817 | biostudies-literature
| S-EPMC10071805 | biostudies-literature
| S-EPMC8263399 | biostudies-literature
| S-EPMC10213584 | biostudies-literature
| S-EPMC9857048 | biostudies-literature
| S-EPMC7469487 | biostudies-literature
| S-EPMC9035563 | biostudies-literature
| S-EPMC7081247 | biostudies-literature
| S-EPMC7060303 | biostudies-literature