Unknown

Dataset Information

0

Microwave-Assisted Freeze-Drying of Monoclonal Antibodies: Product Quality Aspects and Storage Stability.


ABSTRACT: In order to overcome the downside of long conventional freeze-drying (CFD) process times for monoclonal antibody formulations, microwave-assisted freeze-drying (MFD) was introduced. Recently, the general applicability and potential shortening of drying times were shown. However, little is known about the storage stability of MFD products compared to CFD references. Additionally, batch homogeneity issues were seen within MFD in the past. In this study, we examined four different formulations of two different monoclonal antibodies using three different glass-forming excipients: sucrose, trehalose, and arginine phosphate. These formulations were freeze-dried with two different drying protocols (CFD and MFD), stored for 24 weeks, and analyzed for solid-state and protein-related quality attributes. Moreover, a new microwave generator setup was investigated for its potential to improve batch homogeneity. In all investigated formulations, comparable stability profiles were found, although the classical magnetron generator led to inferior batch homogeneity with respect to residual moisture distribution. In contrast, the new MFD setup indicated the potential to approximate batch homogeneity to the level of CFD. However, for future applications, there is an unabated need for new machine designs to comply with pharmaceutical manufacturing requirements.

SUBMITTER: Gitter JH 

PROVIDER: S-EPMC6956074 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Microwave-Assisted Freeze-Drying of Monoclonal Antibodies: Product Quality Aspects and Storage Stability.

Gitter Julian Hendryk JH   Geidobler Raimund R   Presser Ingo I   Winter Gerhard G  

Pharmaceutics 20191212 12


In order to overcome the downside of long conventional freeze-drying (CFD) process times for monoclonal antibody formulations, microwave-assisted freeze-drying (MFD) was introduced. Recently, the general applicability and potential shortening of drying times were shown. However, little is known about the storage stability of MFD products compared to CFD references. Additionally, batch homogeneity issues were seen within MFD in the past. In this study, we examined four different formulations of t  ...[more]

Similar Datasets

| S-EPMC10223035 | biostudies-literature
| S-EPMC7856218 | biostudies-literature
| S-EPMC5503063 | biostudies-other
| S-EPMC3699554 | biostudies-literature
| S-EPMC6920930 | biostudies-literature
| S-EPMC10062427 | biostudies-literature
| S-EPMC7289390 | biostudies-literature
| S-EPMC8932309 | biostudies-literature
| S-EPMC5161340 | biostudies-literature
| S-EPMC8232433 | biostudies-literature