Comparison of liver MRI R2(FerriScan®) VS liver MRI T2* as a measure of body iron load in a cohort of beta thalassaemia major patients.


ABSTRACT: To compare the similarity of the non-patented T2* and the high cost patented R2 (Ferriscan®) MRI techniques in the measurement of liver iron concentration (LIC) in heavily transfused patients with thalassaemia major in a real- life Sri Lankan hospital setup. We compared LIC measured by MRI, obtained 2 weeks apart, using both T2* and R2 techniques in 15 patients with beta thalassaemia major. They all had a history of >?100?units of blood transfusions life long and also a history of sub optimal chelation. MRI R2 and MRI T2* scan values showed a negative correlation (co-rrelation coefficient?=?-?0.63, p?=?0.01) This correlation was strong in lower LICs and progressively decreased with upper LIC values. Thus a significant discrepancy was observed between median values of two MRI technologies (p?=?0.0005) with T2* tending to underestimate iron overload especially in those with very high LIC identified by R2. The lack of concordance of T2* and R2 especially in those with very high reading on R2 suggest the potential errors in interpretations that can occur in "non-expert centres"; which are likely to lead to errors in clinical judgement on the intensity of chelation therapy needed.

SUBMITTER: Padeniya P 

PROVIDER: S-EPMC6977251 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of liver MRI R2(FerriScan®) VS liver MRI T2* as a measure of body iron load in a cohort of beta thalassaemia major patients.

Padeniya Padmapani P   Siriwardana Shirom S   Ediriweera Dileepa D   Samarasinghe Nayana N   Silva Sasanka S   Silva Ishari I   Ahamed Nizri N   Niriella Madunil M   Premawardhena Anuja A  

Orphanet journal of rare diseases 20200122 1


To compare the similarity of the non-patented T2* and the high cost patented R2 (Ferriscan®) MRI techniques in the measurement of liver iron concentration (LIC) in heavily transfused patients with thalassaemia major in a real- life Sri Lankan hospital setup. We compared LIC measured by MRI, obtained 2 weeks apart, using both T2* and R2 techniques in 15 patients with beta thalassaemia major. They all had a history of > 100 units of blood transfusions life long and also a history of sub optimal ch  ...[more]

Similar Datasets

| S-EPMC8573209 | biostudies-literature
| S-EPMC7755713 | biostudies-literature
| S-EPMC4791092 | biostudies-literature
| S-EPMC9653969 | biostudies-literature
| S-EPMC6626578 | biostudies-literature
| S-EPMC2292491 | biostudies-other
| S-EPMC5927847 | biostudies-literature
| S-EPMC2686136 | biostudies-literature
| S-EPMC6218127 | biostudies-literature
| S-EPMC2706154 | biostudies-literature