Validation of a novel Multi-Gas sensor for volcanic HCl alongside H2S and SO2 at Mt. Etna.


ABSTRACT: Volcanic gas emission measurements inform predictions of hazard and atmospheric impacts. For these measurements, Multi-Gas sensors provide low-cost in situ monitoring of gas composition but to date have lacked the ability to detect halogens. Here, two Multi-Gas instruments characterized passive outgassing emissions from Mt. Etna's (Italy) three summit craters, Voragine (VOR), North-east Crater (NEC) and Bocca Nuova (BN) on 2 October 2013. Signal processing (Sensor Response Model, SRM) approaches are used to analyse H2S/SO2 and HCl/SO2 ratios. A new ability to monitor volcanic HCl using miniature electrochemical sensors is here demonstrated. A "direct-exposure" Multi-Gas instrument contained SO2, H2S and HCl sensors, whose sensitivities, cross-sensitivities and response times were characterized by laboratory calibration. SRM analysis of the field data yields H2S/SO2 and HCl/SO2 molar ratios, finding H2S/SO2 = 0.02 (0.01-0.03), with distinct HCl/SO2 for the VOR, NEC and BN crater emissions of 0.41 (0.38-0.43), 0.58 (0.54-0.60) and 0.20 (0.17-0.33). A second Multi-Gas instrument provided CO2/SO2 and H2O/SO2 and enabled cross-comparison of SO2. The Multi-Gas-measured SO2-HCl-H2S-CO2-H2O compositions provide insights into volcanic outgassing. H2S/SO2 ratios indicate gas equilibration at slightly below magmatic temperatures, assuming that the magmatic redox state is preserved. Low SO2/HCl alongside low CO2/SO2 indicates a partially outgassed magma source. We highlight the potential for low-cost HCl sensing of H2S-poor HCl-rich volcanic emissions elsewhere. Further tests are needed for H2S-rich plumes and for long-term monitoring. Our study brings two new advances to volcano hazard monitoring: real-time in situ measurement of HCl and improved Multi-Gas SRM measurements of gas ratios.

SUBMITTER: Roberts TJ 

PROVIDER: S-EPMC6979509 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of a novel Multi-Gas sensor for volcanic HCl alongside H<sub>2</sub>S and SO<sub>2</sub> at Mt. Etna.

Roberts T J TJ   Lurton T T   Giudice G G   Liuzzo M M   Aiuppa A A   Coltelli M M   Vignelles D D   Salerno G G   Couté B B   Chartier M M   Baron R R   Saffell J R JR   Scaillet B B  

Bulletin of volcanology 20170417 5


Volcanic gas emission measurements inform predictions of hazard and atmospheric impacts. For these measurements, Multi-Gas sensors provide low-cost in situ monitoring of gas composition but to date have lacked the ability to detect halogens. Here, two Multi-Gas instruments characterized passive outgassing emissions from Mt. Etna's (Italy) three summit craters, Voragine (VOR), North-east Crater (NEC) and Bocca Nuova (BN) on 2 October 2013. Signal processing (Sensor Response Model, SRM) approaches  ...[more]

Similar Datasets

| S-EPMC4674870 | biostudies-other
| S-EPMC6482307 | biostudies-other
| S-EPMC3787679 | biostudies-literature
| S-EPMC6560784 | biostudies-literature
| S-EPMC6491489 | biostudies-literature
| S-EPMC5339818 | biostudies-literature
| S-EPMC4055905 | biostudies-other
| S-EPMC6297054 | biostudies-literature
| S-EPMC8460648 | biostudies-literature
| S-EPMC8782020 | biostudies-literature