Quality control of multiplex antibody detection in samples from large-scale surveys: the example of malaria in Haiti.


ABSTRACT: Measuring antimalarial antibodies can estimate transmission in a population. To compare outputs, standardized laboratory testing is required. Here we describe the in-country establishment and quality control (QC) of a multiplex bead assay (MBA) for three sero-surveys in Haiti. Total IgG data against 21 antigens were collected for 32,758 participants. Titration curves of hyperimmune sera were included on assay plates, assay signals underwent 5-parameter regression, and inspection of the median and interquartile range (IQR) for the y-inflection point was used to determine assay precision. The medians and IQRs were similar for Surveys 1 and 2 for most antigens, while the IQRs increased for some antigens in Survey 3. Levey-Jennings charts for selected antigens provided a pass/fail criterion for each assay plate and, of 387 assay plates, 13 (3.4%) were repeated. Individual samples failed if IgG binding to the generic glutathione-S-transferase protein was observed, with 659 (2.0%) samples failing. An additional 455 (1.4%) observations failed due to low bead numbers (<20/analyte). The final dataset included 609,438 anti-malaria IgG data points from 32,099 participants; 96.6% of all potential data points if no QC failures had occurred. The MBA can be deployed with high-throughput data collection and low inter-plate variability while ensuring data quality.

SUBMITTER: van den Hoogen LL 

PROVIDER: S-EPMC6981173 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications


Measuring antimalarial antibodies can estimate transmission in a population. To compare outputs, standardized laboratory testing is required. Here we describe the in-country establishment and quality control (QC) of a multiplex bead assay (MBA) for three sero-surveys in Haiti. Total IgG data against 21 antigens were collected for 32,758 participants. Titration curves of hyperimmune sera were included on assay plates, assay signals underwent 5-parameter regression, and inspection of the median an  ...[more]

Similar Datasets

| S-EPMC8225651 | biostudies-literature
| S-EPMC4844712 | biostudies-literature
| S-EPMC8176464 | biostudies-literature
| S-EPMC7082935 | biostudies-literature
| S-EPMC4929498 | biostudies-literature
| S-EPMC2631447 | biostudies-literature
| S-EPMC3144818 | biostudies-literature
| S-EPMC5017679 | biostudies-literature
| S-EPMC10208227 | biostudies-literature
| S-EPMC8476043 | biostudies-literature