Unknown

Dataset Information

0

A bifurcated continuous field-flow fractionation (BCFFF) chip for high-yield and high-throughput nucleic acid extraction and purification.


ABSTRACT: We report a bifurcated continuous field-flow fractionation (BCFFF) chip for high-yield and high-throughput (20 min) extraction of nucleic acids from physiological samples. The design uses a membrane ionic transistor to sustain low-ionic strength in a localized region at a junction, such that the resulting high field can selectively isolate high-charge density nucleic acids from the main flow channel and insert them into a standardized buffer in a side channel that bifurcates from the junction. The high local electric field and the bifurcated field-flow design facilitate concentration reduction of both divalent cation (Ca2+) and molecular PCR inhibitors by more than two orders of magnitude, even with high-throughput continuous loading. The unique design with a large (>20 mM mm-1) on-chip ionic-strength gradient allows miniaturization into a high-throughput field-flow fractionation chip that can be integrated with upstream lysing and downstream PCR/sensor modules for various nucleic acid detection/quantification applications. A concentration-independent 85% yield for extraction and an overall post-PCR yield exceeding 60% are demonstrated for a 111 bp dsDNA in 10 ?L of human plasma, compared to no amplification with the raw sample. A net yield four times larger than a commercial extraction kit is demonstrated for miR-39 in human plasma.

SUBMITTER: Zhang C 

PROVIDER: S-EPMC6982425 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

A bifurcated continuous field-flow fractionation (BCFFF) chip for high-yield and high-throughput nucleic acid extraction and purification.

Zhang Chenguang C   Sun Gongchen G   Senapati Satyajyoti S   Chang Hsueh-Chia HC  

Lab on a chip 20191017 22


We report a bifurcated continuous field-flow fractionation (BCFFF) chip for high-yield and high-throughput (20 min) extraction of nucleic acids from physiological samples. The design uses a membrane ionic transistor to sustain low-ionic strength in a localized region at a junction, such that the resulting high field can selectively isolate high-charge density nucleic acids from the main flow channel and insert them into a standardized buffer in a side channel that bifurcates from the junction. T  ...[more]

Similar Datasets

| S-EPMC434456 | biostudies-literature
| S-EPMC6033430 | biostudies-literature
| S-EPMC6343928 | biostudies-literature
| S-EPMC8141753 | biostudies-literature
| S-EPMC10216157 | biostudies-literature
| S-EPMC8838507 | biostudies-literature
| S-EPMC5453589 | biostudies-literature
| S-EPMC4830504 | biostudies-literature
| S-EPMC6281648 | biostudies-literature
| S-EPMC6080726 | biostudies-literature