Unknown

Dataset Information

0

Measuring the density of iodine depositions: Detecting an invisible residual tumor after conventional transarterial chemoembolization.


ABSTRACT: PURPOSE:The purpose of this study is to evaluate the use of density measurements in the diagnosis of an underlying residual tumor beyond iodine depositions after Lipiodol-based conventional transarterial chemoembolization (cTACE). METHOD AND MATERIALS:Thirty follow-up CT scans of 20 patients 6-12 weeks after Lipiodol-based cTACE, receiving a digital subtraction angiography at the same time, were analyzed. Reference for the detection of a residual tumor was the angiography, and a visible contrast enhancement was categorized as a residual tumor (n = 16 with residual tumor; n = 14 without residual tumor). The density of the iodine depositions was measured in all containing slices in non-contrast-, arterial- and portal venous-phase CT scans, with a slice thickness of 5.00 mm. The mean density of the iodine deposition during the portal venous phase was subtracted from the mean density of the arterial phase to calculate the density changes (a positive enhancement score represents washout in the portal venous phase). In addition, a quotient relating to the non-contrast measurement was evaluated. RESULTS:Patients with a residual tumor displayed significantly higher enhancement scores in favor of density reduction between the arterial and portal venous phases, compared to patients without a residual tumor (1.41 ± 3.59, n = 14 vs. -13.97 ± 2.88, n = 16; p-value < 0.01). Furthermore, 87.75% of patients with an enhancement score higher than -1.00 (n = 9) had a residual tumor, whereas 100.00% of patients with an enhancement score lower than -20.00 (n = 6) were shown to be tumor-free. The enhancement score quotient resulted in similar findings. CONCLUSION:After cTACE in patients with hepatocellular carcinoma (HCC), the presence of a viable tumor correlated with enhancement scores based on the density measurements of iodine depositions in different phases of the CT scan. Low enhancement scores were associated with completely treated tumors and can aid the decision process to avoid possibly unnecessary angiographies.

SUBMITTER: Haubold J 

PROVIDER: S-EPMC6988944 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6689910 | biostudies-literature
| S-EPMC7324959 | biostudies-literature
| S-EPMC7845953 | biostudies-literature
| S-EPMC8008112 | biostudies-literature
| S-EPMC8382629 | biostudies-literature
| S-EPMC7822566 | biostudies-literature
| S-EPMC6943446 | biostudies-literature
| S-EPMC6890698 | biostudies-literature
| S-EPMC5930180 | biostudies-literature
| S-EPMC3036492 | biostudies-literature