Unknown

Dataset Information

0

Otto: a 4.04?GBq (109?mCi) 68Ge/68Ga generator, first of its kind - extended quality control and performance evaluation in the clinical production of [68Ga]Ga-PSMA-11.


ABSTRACT: BACKGROUND:Here we report on the comprehensive quality control of a 4.04?GBq (109?mCi) generator supplied by itG (Munich, Germany), and used for routine production of [68Ga]Ga-PSMA-11 for clinical imaging. The performance of the 4.04?GBq itG 68Ge/68Ga generator was studied for a year and parameters including elution yield, elution profile, radioactive and stable contaminants were collected. The production yields of a series of 175 [68Ga]Ga-PSMA-11 clinical batches are also reported herein. RESULTS:This first-of-its-kind GMP grade 68Ge/68Ga generator from itG with a nominal activity of 4.04?GBq (109?mCi) showed a stable 68Ga elution profile with elution efficiency averaging 58.3?±?3.7%. 68Ge contaminant in the eluent slightly increased over time but remained 100x lower than those reported for comparable 1.85?GBq (50?mCi) itG generators. Metal impurities were found in concentrations lower than 100?ng/ml (ppb) throughout the study. [68Ga]Ga-PSMA-11 was obtained in 89?±?4% radiochemical yields and?>?99% radiochemical and chemical purities. CONCLUSION:4.04?GBq (109?mCi) itG 68Ge/68Ga generator is suitable for routinely produced 68Ga tracers used in the clinic. Up to 30% higher amount of final drug product was obtained as compared to the 1.85?GBq (50?mCi) itG generator, and as a result larger number of studies could be performed, while reducing the synthetic burden.

SUBMITTER: Waterhouse NN 

PROVIDER: S-EPMC6997319 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Otto: a 4.04 GBq (109 mCi) <sup>68</sup>Ge/<sup>68</sup>Ga generator, first of its kind - extended quality control and performance evaluation in the clinical production of [<sup>68</sup>Ga]Ga-PSMA-11.

Waterhouse Nicole N NN   Amor-Coarasa Alejandro A   Nikolopoulou Anastasia A   Babich John W JW  

EJNMMI radiopharmacy and chemistry 20200203 1


<h4>Background</h4>Here we report on the comprehensive quality control of a 4.04 GBq (109 mCi) generator supplied by itG (Munich, Germany), and used for routine production of [<sup>68</sup>Ga]Ga-PSMA-11 for clinical imaging. The performance of the 4.04 GBq itG <sup>68</sup>Ge/<sup>68</sup>Ga generator was studied for a year and parameters including elution yield, elution profile, radioactive and stable contaminants were collected. The production yields of a series of 175 [<sup>68</sup>Ga]Ga-PSMA  ...[more]

Similar Datasets

| S-EPMC7048889 | biostudies-literature
| S-EPMC5560715 | biostudies-other
| S-EPMC8391978 | biostudies-literature
| S-EPMC10216693 | biostudies-literature
| S-EPMC7557882 | biostudies-literature
| S-EPMC7724278 | biostudies-literature
| S-EPMC9295986 | biostudies-literature
| S-EPMC5355341 | biostudies-literature
| S-EPMC9035563 | biostudies-literature
| S-EPMC6278899 | biostudies-other