Mandić Mirko M Rullman Eric E Widholm Per P Lilja Mats M Dahlqvist Leinhard Olof O Gustafsson Thomas T Lundberg Tommy R TR
Scientific reports 20200210 1
This study aimed to validate a fully automatic method to quantify knee-extensor muscle volume and exercise-induced hypertrophy. By using a magnetic resonance imaging-based fat-water separated two-point Dixon sequence, the agreement between automated and manual segmentation of a specific ~15-cm region (partial volume) of the quadriceps muscle was assessed. We then explored the sensitivity of the automated technique to detect changes in both complete and partial quadriceps volume in response to 8 ...[more]