Cavity Ring-Down Methane Sensor for Small Unmanned Aerial Systems.


ABSTRACT: We present the development, integration, and testing of an open-path cavity ring-down spectroscopy (CRDS) methane sensor for deployment on small unmanned aerial systems (sUAS). The open-path configuration used here (without pump or flow-cell) enables a low mass (4 kg) and low power (12 W) instrument that can be readily integrated to sUAS, defined here as having all-up mass of <25 kg. The instrument uses a compact telecom style laser at 1651 nm (near-infrared) and a linear 2-mirror high-finesse cavity. We show test results of flying the sensor on a DJI Matrice 600 hexacopter sUAS. The high sensitivity of the CRDS method allows sensitive methane detection with a precision of ~10-30 ppb demonstrated for actual flight conditions. A controlled release setup, where known mass flows are delivered, was used to simulate point-source methane emissions. Examples of methane plume detection from flight tests suggest that isolated plumes from sources with a mass flow as low as ~0.005 g/s can be detected. The sUAS sensor should have utility for emissions monitoring and quantification from natural gas infrastructure. To the best of our knowledge, it is also the first CRDS sensor directly deployed onboard an sUAS.

SUBMITTER: Martinez B 

PROVIDER: S-EPMC7014388 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cavity Ring-Down Methane Sensor for Small Unmanned Aerial Systems.

Martinez Benjamin B   Miller Thomas W TW   Yalin Azer P AP  

Sensors (Basel, Switzerland) 20200114 2


We present the development, integration, and testing of an open-path cavity ring-down spectroscopy (CRDS) methane sensor for deployment on small unmanned aerial systems (sUAS). The open-path configuration used here (without pump or flow-cell) enables a low mass (4 kg) and low power (12 W) instrument that can be readily integrated to sUAS, defined here as having all-up mass of <25 kg. The instrument uses a compact telecom style laser at 1651 nm (near-infrared) and a linear 2-mirror high-finesse c  ...[more]

Similar Datasets

| S-EPMC6864454 | biostudies-literature
| S-EPMC6375938 | biostudies-literature
| S-EPMC6392284 | biostudies-other
| S-EPMC4934319 | biostudies-literature
| S-EPMC5929499 | biostudies-literature
| S-EPMC3566131 | biostudies-literature
| S-EPMC7348723 | biostudies-literature
| S-EPMC5795605 | biostudies-literature
| S-EPMC7308845 | biostudies-literature
| S-EPMC8071494 | biostudies-literature