Unknown

Dataset Information

0

Magnetic Needle Steering in Soft Phantom Tissue.


ABSTRACT: Needle steering is a technology for guiding needles around sensitive internal obstacles in minimally invasive surgery. Traditional techniques apply rotation at the base of a needle with an asymmetric tip, enabling steering through the redirection of radial forces. Magnetic steering of catheters and continuum manipulators is another technology that allows steering of a shaft in the body. Both of these techniques rely on mechanical or manual shaft advancement methods. Needle steering has not achieved widespread clinical use due to several limitations: 1- buckling and compression effects in the shaft and needle rotation cause excessive tissue damage; 2- torsion effects on the shaft and needle deflection at tissue boundaries lead to difficulty in control; and 3- restricted radius of curvature results in limited workspace. Magnetically steered catheters and continuum manipulators also suffer from limited curvature and the possibility of buckling. This paper proposes a novel needle steering method empowered by electromagnetic actuation that overcomes all of the aforementioned limitations, making it a promising option for further study toward healthcare applications.

SUBMITTER: Ilami M 

PROVIDER: S-EPMC7016187 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Magnetic Needle Steering in Soft Phantom Tissue.

Ilami Mahdi M   Ahmed Reza James RJ   Petras Alex A   Beigzadeh Borhan B   Marvi Hamid H  

Scientific reports 20200212 1


Needle steering is a technology for guiding needles around sensitive internal obstacles in minimally invasive surgery. Traditional techniques apply rotation at the base of a needle with an asymmetric tip, enabling steering through the redirection of radial forces. Magnetic steering of catheters and continuum manipulators is another technology that allows steering of a shaft in the body. Both of these techniques rely on mechanical or manual shaft advancement methods. Needle steering has not achie  ...[more]

Similar Datasets

| S-EPMC6386781 | biostudies-literature
| S-EPMC4409936 | biostudies-literature
| S-EPMC5545809 | biostudies-other
| S-EPMC6697175 | biostudies-literature
| S-EPMC7755224 | biostudies-literature
| S-EPMC8455490 | biostudies-literature
| S-EPMC8455397 | biostudies-literature
| S-EPMC8252537 | biostudies-literature
| S-EPMC6858400 | biostudies-literature
| S-EPMC7478958 | biostudies-literature