Unknown

Dataset Information

0

Accuracy of Three Impression Materials on the Totally Edentulous Maxilla: In Vitro/In Silico Comparative Analysis.


ABSTRACT: BACKGROUND:This study was aimed at comparing the accuracy of impressions of a reference typodont (RT) reproducing a totally edentulous maxilla made with three impression materials: polysulfide, polyether, and polyvinyl-siloxane. METHODS:The RT was scanned using a desktop scanner, obtaining a reference scan. Ten impressions for each of the three tested materials were made using a mechanical device with a standardized and consistent modality. A laboratory scanner performed the digitization of each impression. We produced digital models by processing "in reverse" the scans of the physical impressions using a dedicated software, obtaining three groups (n = 10), respectively. The groups were titled: "polysulfide," "polyvinyl-siloxane," and "polyether." The scans in .stl format were imported into Geomagic Control X and then compared to RT to evaluate the accuracy of each scan by calculating trueness and precision in µm. Recorded data were subjected to descriptive statistics. RESULTS:Trueness (arithmetic proximity) values (95%CI) were: polysulfide = 249.9 (121.3-378.5), polyvinyl-siloxane = 216.8 (123.1-310.6), polyether = 291.1 (219.9-362.3). Precision values (95% CI) were: polysulfide = 261.9 (108.8-415), polyvinyl-siloxane = 209.4 (111.9-306.8), polyether = 283 (227.9-338.1). Statistically significant differences were not detected between the means of the experimental groups, both for trueness and precision. CONCLUSIONS:The accuracy of the scans obtained from polyvinyl-siloxane, polysulfide, and polyether impressions can be considered comparable in a fully edentulous maxilla.

SUBMITTER: Zarone F 

PROVIDER: S-EPMC7040790 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of Three Impression Materials on the Totally Edentulous Maxilla: In Vitro/In Silico Comparative Analysis.

Zarone Fernando F   Ruggiero Gennaro G   Di Mauro Maria Irene MI   Spagnuolo Gianrico G   Ferrari Marco M   Sorrentino Roberto R  

Materials (Basel, Switzerland) 20200122 3


<h4>Background</h4>This study was aimed at comparing the accuracy of impressions of a reference typodont (RT) reproducing a totally edentulous maxilla made with three impression materials: polysulfide, polyether, and polyvinyl-siloxane.<h4>Methods</h4>The RT was scanned using a desktop scanner, obtaining a reference scan. Ten impressions for each of the three tested materials were made using a mechanical device with a standardized and consistent modality. A laboratory scanner performed the digit  ...[more]

Similar Datasets

| S-EPMC5350296 | biostudies-literature
| S-EPMC8073328 | biostudies-literature
| S-EPMC9655800 | biostudies-literature
| S-EPMC7046187 | biostudies-literature
| S-EPMC7143836 | biostudies-literature
| S-EPMC7500567 | biostudies-literature
| S-EPMC5681799 | biostudies-literature
| S-EPMC7137345 | biostudies-literature
| S-EPMC7509929 | biostudies-literature
| S-EPMC4246377 | biostudies-literature