Unknown

Dataset Information

0

Novel Irrigated Temperature-Controlled Lattice Ablation Catheter for Ventricular Ablation: A Preclinical Multimodality Biophysical Characterization.


ABSTRACT: BACKGROUND:Ventricular tachycardia ablation is often limited by insufficient lesion creation. A novel radiofrequency catheter with an expandable lattice electrode has a larger surface area capable of delivering higher currents at a lower density to potentially increase lesion dimensions without overheating. METHODS:This 8F bidirectional irrigated catheter (Sphere-9, Affera Inc) has a 9 mm spherical lattice tip ("lattice") with an effective surface area 10-fold larger than standard linear catheters. Nine surface thermocouples provide temperature feedback to a proprietary high-current generator operating in a temperature-controlled mode. Ex vivo phase: in 11 bovine hearts, unipolar ablation at 30, 60, and 120 seconds was compared between the lattice (Tmax60°C) and a standard linear irrigated-tip catheter (40 W) at contact force of 10 g. In 5 porcine hearts, bipolar ablation was compared between the catheters (Tmax60°C versus 40 W; 60 seconds). In vivo phase: in 9 swine, ventricular ablation at Tmax60°C versus 40 W was performed for 60 seconds. In addition, direct tissue temperature at 3- and 7-mm tissue depth was measured in a thigh muscle preparation. RESULTS:Ex vivo: lattice produced deeper lesions at 30, 60, and 120 seconds application duration (6.7±1.3 versus 4.8±1.2 mm; 8.3±1.4 versus 5.4±0.8 mm; 10.0±1.6 versus 6.1±1.6 mm, respectively, P?0.001 for all). Bipolar lesions were deeper (15.8±4.1 versus 10.5±1.4 mm, P<0.001) and more likely to be transmural (80% versus 0%, P=0.002). In vivo: lattice produced deeper lesions (10.5±1.4 versus 6.5±0.8 mm, P?0.001). Tissue temperature at 7 mm was higher with the lattice (+15.1±2.4°C; P<0.001). The steam-pop occurrence was lower with the lattice (total: 4% versus 18%, P=0.02; in vivo 0% versus 14.2%, P=0.13). CONCLUSIONS:This novel radiofrequency system produces larger ventricular lesions compared with standard irrigated catheters and at a lower risk of tissue overheating. This may improve the efficacy of ventricular tachycardia ablation procedures while reducing the number of applications and procedural duration.

SUBMITTER: Shapira-Daniels A 

PROVIDER: S-EPMC7043000 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Novel Irrigated Temperature-Controlled Lattice Ablation Catheter for Ventricular Ablation: A Preclinical Multimodality Biophysical Characterization.

Shapira-Daniels Ayelet A   Barkagan Michael M   Yavin Hagai H   Sroubek Jakub J   Reddy Vivek Y VY   Neuzil Petr P   Anter Elad E  

Circulation. Arrhythmia and electrophysiology 20191111 11


<h4>Background</h4>Ventricular tachycardia ablation is often limited by insufficient lesion creation. A novel radiofrequency catheter with an expandable lattice electrode has a larger surface area capable of delivering higher currents at a lower density to potentially increase lesion dimensions without overheating.<h4>Methods</h4>This 8F bidirectional irrigated catheter (Sphere-9, Affera Inc) has a 9 mm spherical lattice tip ("lattice") with an effective surface area 10-fold larger than standard  ...[more]

Similar Datasets

| S-EPMC4326034 | biostudies-literature
| S-EPMC7896466 | biostudies-literature
| S-EPMC3298677 | biostudies-literature
| S-EPMC8068636 | biostudies-literature
| S-EPMC4114331 | biostudies-literature
| S-EPMC7358957 | biostudies-literature
| S-EPMC8174287 | biostudies-literature
| S-EPMC7285871 | biostudies-literature
| S-EPMC7772601 | biostudies-literature
| S-EPMC6575819 | biostudies-literature