No radiographic index predicts difficult intubation using the Optiscope™ in cervical spine surgery patients: a retrospective study.


ABSTRACT: BACKGROUND:The Optiscope™ can be used for intubation with minimal neck motion. We retrospectively investigated radiographic predictors of difficult intubation using the Optiscope™ by analyzing preoperative radiographic images. METHODS:One hundred eighty-four patients who were intubated with the Optiscope™ under manual in-line cervical stabilization for cervical spine surgery were enrolled. Radiographic indices were measured on preoperative cervical spine lateral X-ray and magnetic resonance imaging images. Difficult intubation was defined as failure or time consumption more than 90?s on the first attempt. To identify significant predictors of difficult intubation using the Optiscope™ and evaluate their diagnostic value, multivariable logistic regression and receiver operating characteristic analyses were used. RESULTS:Fourty-seven patients showed difficult intubation. There was no significant difference in radiographic indices between the difficult and easy intubation groups, but higher body mass index (BMI) (26.5 [3.0] vs. 24.6 [3.5] kg/m2, P?=?0.001), shorter sternomental distance (SMD) (122.0 [104.0 to 150.0] vs. 150.0 [130.0 to 170.0] mm, P?=?0.001), shorter interincisor gap (40.0 [35.0 to 45.0] vs. 43.0 [40.0 to 50.0] mm, P?=?0.006), and higher incidence of excessive oral secretions (10.6% vs. 2.9%, P?=?0.049) were observed in patients with difficult intubation. In multivariable analysis, BMI (odds ratio [95% confidence interval]; 1.15 [1.03 to 1.28], P?=?0.011) and SMD (odds ratio [95% confidence interval]; 0.98 [0.97 to 1.00], P?=?0.008) were associated with difficult intubation with the Optiscope™. In receiver operating characterstic analysis, the area under the curve for body mass index was 0.68 (95% confidence interval; 0.60 to 0.77, P?

SUBMITTER: Oh H 

PROVIDER: S-EPMC7043025 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

No radiographic index predicts difficult intubation using the Optiscope™ in cervical spine surgery patients: a retrospective study.

Oh Hyongmin H   Kim Hansol H   Yoon Hyun-Kyu HK   Lee Hyung-Chul HC   Park Hee-Pyoung HP  

BMC anesthesiology 20200226 1


<h4>Background</h4>The Optiscope™ can be used for intubation with minimal neck motion. We retrospectively investigated radiographic predictors of difficult intubation using the Optiscope™ by analyzing preoperative radiographic images.<h4>Methods</h4>One hundred eighty-four patients who were intubated with the Optiscope™ under manual in-line cervical stabilization for cervical spine surgery were enrolled. Radiographic indices were measured on preoperative cervical spine lateral X-ray and magnetic  ...[more]

Similar Datasets

| S-EPMC4372550 | biostudies-literature
| S-EPMC4110170 | biostudies-literature
| S-EPMC4771508 | biostudies-other
| S-EPMC7154345 | biostudies-literature
| S-EPMC4995029 | biostudies-literature
| S-EPMC4342401 | biostudies-literature
| S-EPMC6807304 | biostudies-literature
| S-EPMC5520595 | biostudies-other
| S-EPMC5410055 | biostudies-literature
| S-EPMC6739276 | biostudies-literature