Unknown

Dataset Information

0

Accuracy of unguided and ultrasound guided Coracohumeral ligament infiltrations - a feasibility cadaveric case series.


ABSTRACT: BACKGROUND:Coracohumeral ligament (CHL) thickening, contracture, and fibroplasia have been identified in glenohumeral idiopathic adhesive capsulitis (GHIAC). The CHL is the main structure responsible for the range of motion limitations. Favorable outcomes have been reported with CHL surgical release. Intra-articular glenohumeral joint corticosteroid infiltrations are utilized to disrupt the inflammatory process and reduce pain in GHIAC. The aim of this study was to investigate whether the CHL could be accurately targeted with a periligamentous infiltration. METHODS:A convenience sample of 12 unembalmed cadaver shoulders (mean age: 74.5?years, range 66-87?years) without evidence of previous injury or surgery were utilized in this exploratory double factor feasibility cadaveric (unguided and ultrasound (US) guided) case series. Two clinicians trained in musculoskeletal infiltration techniques carried out the infiltrations on each shoulder with colored latex. One clinician infiltrated without guidance, the other with US-guidance. The injecting clinicians were blinded to the others infiltration procedure and the order was randomized. An anatomist blinded to the infiltration order performed a shoulder dissection and recorded the infiltrate location. Percentage calculation for accuracy of infiltration and a chi-square evaluation of the difference between unguided and US-guided infiltrations was applied. RESULTS:An accuracy of 75% was achieved for unguided infiltration and 80% for US-guided infiltration techniques. Chi-squared indicated there was no significant difference (p?= 0.82) between the unguided and US-guided techniques. CONCLUSION:US-guided and unguided infiltrations achieved good accuracy targeting the CHL, suggesting infiltrations can specifically and accurately target the CHL. In vivo investigation using such infiltration techniques are warranted.

SUBMITTER: Pape JL 

PROVIDER: S-EPMC7049223 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of unguided and ultrasound guided Coracohumeral ligament infiltrations - a feasibility cadaveric case series.

Pape John L JL   Boudier-Revéret Mathieu M   Brismée Jean-Michel JM   Gilbert Kerry K KK   Grabs Detlev D   Sobczak Stéphane S  

BMC musculoskeletal disorders 20200228 1


<h4>Background</h4>Coracohumeral ligament (CHL) thickening, contracture, and fibroplasia have been identified in glenohumeral idiopathic adhesive capsulitis (GHIAC). The CHL is the main structure responsible for the range of motion limitations. Favorable outcomes have been reported with CHL surgical release. Intra-articular glenohumeral joint corticosteroid infiltrations are utilized to disrupt the inflammatory process and reduce pain in GHIAC. The aim of this study was to investigate whether th  ...[more]

Similar Datasets

| S-EPMC8626355 | biostudies-literature
| S-EPMC9671893 | biostudies-literature
| S-EPMC5785948 | biostudies-literature
| S-EPMC6620624 | biostudies-literature
| S-EPMC6051955 | biostudies-literature
| S-EPMC8007447 | biostudies-literature
| S-EPMC7583166 | biostudies-literature
| S-EPMC8254201 | biostudies-literature
| S-EPMC8527325 | biostudies-literature