Accuracy of the Apple Watch 4 to Measure Heart Rate in Patients With Atrial Fibrillation.


ABSTRACT: Background Wearable wrist-monitors offer an unobtrusive way to acquire heart rate data in an efficient manner. Previous work in this field has focused on studying healthy subjects during exercise but has yet to assess the efficacy of these devices in patients suffering from common cardiac arrhythmias such as atrial fibrillation. Objective The objective of this pilot study was to assess the accuracy of the Apple Watch heart rate monitor in fifty patients experiencing atrial fibrillation compared to telemetry. Results Results from this pilot clinical study demonstrated a correlation coefficient of 0.7 between all readings on the Apple Watch and telemetry. Furthermore, the Apple Watch assessed heart rate more accurately in patients who were in atrial fibrillation than in those that were not (rc = 0.86, patients in AF, vs. rc = 0.64, patients not in AF). Clinical Impact The presented data from this pilot study suggests that caution should be noted before using the Apple Watch 4 wearable wrist monitor to monitor heart rate in patients with cardiac arrhythmias such as atrial fibrillation.

SUBMITTER: Seshadri DR 

PROVIDER: S-EPMC7049290 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of the Apple Watch 4 to Measure Heart Rate in Patients With Atrial Fibrillation.

Seshadri Dhruv R DR   Bittel Barb B   Browsky Dalton D   Houghtaling Penny P   Drummond Colin K CK   Desai Milind M   Gillinov A Marc AM  

IEEE journal of translational engineering in health and medicine 20191213


Background Wearable wrist-monitors offer an unobtrusive way to acquire heart rate data in an efficient manner. Previous work in this field has focused on studying healthy subjects during exercise but has yet to assess the efficacy of these devices in patients suffering from common cardiac arrhythmias such as atrial fibrillation. Objective The objective of this pilot study was to assess the accuracy of the Apple Watch heart rate monitor in fifty patients experiencing atrial fibrillation compared  ...[more]

Similar Datasets

| S-EPMC8890343 | biostudies-literature
| S-EPMC11327451 | biostudies-literature
| S-EPMC8850821 | biostudies-literature
| S-EPMC7509607 | biostudies-literature
| S-EPMC9269674 | biostudies-literature
| S-EPMC7046516 | biostudies-literature
| S-EPMC8175975 | biostudies-literature
2018-04-12 | GSE113013 | GEO
| S-EPMC5910663 | biostudies-literature
| S-EPMC9715872 | biostudies-literature